PassFinder AP2520 VoIP Router/Gateway Operation Manual
Version 1.10 / Mar. 2002
AddPac Technology Co., Ltd.
-
252
-
5.7.3.9.1.
Syntax
Keyword / Argument
Description
number
Number of rings detected before answering the
call.
Valid entries are numbers from 1 to 255.
The default is 1.
5.7.3.9.2.
Default Value
One Ring
5.7.3.9.3.
Command Mode
Voice-port configuration Mode
5.7.3.9.4.
Usage Guideline
Use the
ring number
command to set the maximum number of rings to be
detected before answering a call over an FXO voice port. Use the
no
form of
this command to reset the default value, which is one ring.Normally, this
command should be set to the default so that incoming calls are answered
quickly. If you have other equipment available on the line to answer incoming
calls, you might want to set the value higher to give the equipment sufficient
time to respond. In that case, the FXO interface would answer if the equipment
on line did not answer the incoming call in the configured number of rings.This
command is not applicable to FXS or E&M interfaces because they do not
receive ringing to receive a call.
5.7.3.9.5.
Examples
The following example on the router sets five rings as the maximum number of
rings to be detected before closing a connection over this voice port:
voice-port 1/1
ring number 5