Logger Port Function
Logger Port Function
The Model 4048 and Model 4020 systems diagnostics log (output of the Logger port)
shows system configuration changes (slots going active or inactive) and errors. This is the
same output as the history log with Card Configuration reports included.
ANI Signaling
Automatic Number Identification (ANI) signals are voice band data signals that are
transmitted from a mobile or portable radio to the consoles. The types of signaling
methods are DTMF, 5/6 Tone, GE-STAR, and MDC-1200. ANI signaling is decoded on
the DCC and forwarded to each console via the CIC card.
For more information about ANI and signaling methods, see