Associating an Aux. Output with a Standard Aux. Input
The field labeled “On input, output to Aux Output” is used to activate an output when the
input becomes active. Choose the desired output from the drop-down list of available
outputs.
Enabling the Alarm Display (Standard and Intercom Inputs)
The Alarm Input Mode field allows you to select if and under what conditions an input
displays an alarm message on the console screen. There are four alarm display options:
Table 97: Dual Alarm States
Input A, which must be an odd-numbered input, should be labeled as the alarm condition
input. Input B, which must be an even-numbered input, should be labeled as the Fault
condition input.
For this type of alarm, the inactive and active colors should be set to GREEN and RED
respectively. Then the display of the two inputs will be as shown in
.
Table 98: Dual Alarm Displays
Note
If the outputs have not yet been defined, you will have to come
back to this point later to choose the output.
None
The input will not cause an alarm message display.
Active
The input will display an alarm message when the input transitions
from inactive to active.
Inactive
The input will display an alarm message when the input transitions
from active to inactive.
Dual
This special type of alarm input requires that two consecutive inputs
(Input A and Input B) present the alarm status shown in
.
State
Input A
Input B
Condition
1
Inactive
Active
No Alarm/No Fault
2
Active
Inactive
Alarm
3
Active
Active
Fault
State
Input A
Input B
Condition
1
GREEN
GREEN
No Alarm/No Fault
2
RED
GREEN
Alarm
3
GREEN
RED
Fault
Summary of Contents for 4000 Series
Page 1: ...Series 4000 Communication Control System Installation and Configuration 025 9533Y...
Page 6: ...6 025 9533Y...
Page 28: ...Introduction 28 025 9533Y...
Page 88: ...Common Control Equipment Installation 88 025 9533Y Figure 22 Console Duplex Wall Jacks...
Page 110: ...Common Control Equipment Installation 110 025 9533Y...
Page 172: ...Console Installation 172 025 9533Y...
Page 192: ...Audio Level Adjustments 192 025 9533Y...
Page 230: ...Accessory Installation 230 025 9533Y...
Page 236: ...Console ANI Programming 236 025 9533Y...
Page 339: ...339 RSMP Operation Figure 99 Main Screen...
Page 350: ...Radio System Management Program 350 025 9533Y...
Page 362: ...Appendix B Troubleshooting 362 025 9533Y...
Page 418: ...Index 418 025 9533Y...