73
Auxiliary I/O Card Installation (Optional)
Intercom Interface
The instructions in this section are somewhat generic. If you are configuring an Aux I/O
Card specifically for use with a Zetron Intercom Interface, see the
Series 4000 and Model
4010 Intercom Interface Product Manual
(P/N 025-9331 rev C or newer). That manual
provides installation, configuration, and programming instructions that are much more
specific to that task.
Electrical Specifications
Outputs
(12 per card)
Optically Isolated Inputs
(8 per card)
Nonisolated Inputs
(32 per card)
IRIG B Decoder
(One connection per system)
Relay Contact Current: 1.0 A
Isolation Voltage:
50V with respect to system ground and
between contacts
“On” Current Range:
+5 to +10 mA
“Off” Current Range:
-15 to +1 mA
Maximum Positive Current: +15 mA continuous, +40 mA peak
Maximum Negative
Current:
-15 mA continuous, -40 mA peak
Equivalent Series
Resistance:
405
plus a 0.7-volt drop (forward)
Isolation Voltage:
100V with respect to system ground
Inactive Voltage Range:
+3.5 to +30V
Active Voltage Range:
-30V to +0.9V
Equivalent Parallel
Resistance:
8.2K
pulled to +11.5V
Input Amplitude: 1 to 4 V
pp
Summary of Contents for 4000 Series
Page 1: ...Series 4000 Communication Control System Installation and Configuration 025 9533Y...
Page 6: ...6 025 9533Y...
Page 28: ...Introduction 28 025 9533Y...
Page 88: ...Common Control Equipment Installation 88 025 9533Y Figure 22 Console Duplex Wall Jacks...
Page 110: ...Common Control Equipment Installation 110 025 9533Y...
Page 172: ...Console Installation 172 025 9533Y...
Page 192: ...Audio Level Adjustments 192 025 9533Y...
Page 230: ...Accessory Installation 230 025 9533Y...
Page 236: ...Console ANI Programming 236 025 9533Y...
Page 339: ...339 RSMP Operation Figure 99 Main Screen...
Page 350: ...Radio System Management Program 350 025 9533Y...
Page 362: ...Appendix B Troubleshooting 362 025 9533Y...
Page 418: ...Index 418 025 9533Y...