215
Using CPSW
2. Use the up and down arrows next to the
Position
number to select the position to
configure.
3. Click
Display Operation
.
The Display Operation dialog window opens.
4. Choose a display option.
5. Click
Done
when you are finished.
Miscellaneous
The
Miscellaneous
button opens a dialog window containing miscellaneous configuration
settings.
To configure miscellaneous settings
1. Click
Edit, Position Configuration
.
2. Use the up and down arrows next to the
Position
number to select the position to
configure.
3. Click
Miscellaneous
.
The Miscellaneous dialog window opens.
4. Configure the miscellaneous settings as needed. The following table explains each
setting:
Audio Source for
‘Soft’ Transmit Keys
This option allows you to specify the transmit audio source (microphone) when a
“soft” transmit key is activated. A “soft” transmit key is a programmable key which
has been defined as a transmit key. Choose one of the following audio sources to
assign it to ‘Soft’ transmit keys:
• Dynamic Mic - Use a deskmic or gooseneck microphone connected to the D-Mic
input on the console.
• Electret Mic - Use a handset or headset.
• Spare Input #9 steered - Use whichever audio source that Spare Input #9 is
switched to. Spare Input #9 is the mic switch input on the headset box connector
on the console back panel (J4-pin 9 on the Model 4118 and J1-pin 9 on the Model
4018).
• Hookswitch steers... - Use whichever audio source that the hookswitch is switched
to. Hookswitch is the ear switch input on the headset box connector on the console
back panel (J4-pin 8 on the Model 4118 and J1-pin 8 on the Model 4018).
Instant Select Key
Display Mode
This option allows you to set the green LED for the selected Channel/Frequency to
either flash on/off or stay constantly lit. This option changes the display behavior
only; there is no operational difference.
Received ‘CALL’
light duration
Enter the number of seconds (1-60) that the console “call” light indicator remains on
after the channel call light has extinguished.
Since the channel call light is typically on for three seconds (set by VOX hold time)
after the end of a call, the time entered here is in addition to the three seconds. For
example, if you enter 12 here, the console call light indicator would remain on for 15
seconds after the end of the incoming call.
Summary of Contents for 4000 Series
Page 1: ...Series 4000 Communication Control System Installation and Configuration 025 9533Y...
Page 6: ...6 025 9533Y...
Page 28: ...Introduction 28 025 9533Y...
Page 88: ...Common Control Equipment Installation 88 025 9533Y Figure 22 Console Duplex Wall Jacks...
Page 110: ...Common Control Equipment Installation 110 025 9533Y...
Page 172: ...Console Installation 172 025 9533Y...
Page 192: ...Audio Level Adjustments 192 025 9533Y...
Page 230: ...Accessory Installation 230 025 9533Y...
Page 236: ...Console ANI Programming 236 025 9533Y...
Page 339: ...339 RSMP Operation Figure 99 Main Screen...
Page 350: ...Radio System Management Program 350 025 9533Y...
Page 362: ...Appendix B Troubleshooting 362 025 9533Y...
Page 418: ...Index 418 025 9533Y...