247
Operator Position Installation
License File Installation
The license file “enables” the IntegratorRD software and must be installed for the software
to operate. For more detailed information about software licenses, refer to
Obtaining a
Zetron Software License
(P/N 011-0622). If you have additional questions, contact Zetron
Technical Support for assistance.
Display Resolution Setting
The preferred video display resolution is 1024 x 768, although 800 x 600 is acceptable.
However, at 800 x 600 the console window fills the entire monitor screen making it more
difficult to access other applications. Additionally, the palette must be set to 65536 colors
(“16-bit” color) or higher.
To set the display resolution, open the Windows Display control panel, and then click on
the
Settings
tab. Adjust the slide control labeled
Desktop Area
to a resolution of 1024 x
768 pixels (or your desired resolution). Select
65536 colors
from the drop down list
labeled
Color Palette
. When finished, click
OK
. Windows may suggest that you restart
the computer.
Touch Screen Set Up
A touch screen monitor or flat panel compatible with Windows may be used with the
Integrator Radio Dispatch software. When properly installed, touches on the monitor or
panel are translated into mouse actions and received by the Radio Dispatch Software. In
general, any touch-screen monitor that can be integrated with Windows to translate screen
“touches” into mouse events is compatible with the Integrator Radio Dispatch software.
Network Set Up
Because networking is an inherent feature of Windows, it may be useful to configure the
PCs used by the console positions into a private network. This can help considerably in the
management of the console configurations. Connecting an IntegratorRD workstation to
any public network is not recommended.
Windows XP Settings
Windows XP has some features that should be disabled for using IntegratorRD. The
following steps assume you are using Windows XP Professional with Service Pack 3.
To disable Fast User Switching
1. Click the
Windows Start Button
,
Control Panel
,
Performance Maintenance
,
and
Administrative Tools
.
2. Double click
Services
,
Fast User Switching
. The
Properties
window opens.
3. At
Service Status
select
Stop
.
4. Set
Startup Type
to
Disabled
.
5. Click
Apply
, then
OK
.
Summary of Contents for 4000 Series
Page 1: ...Series 4000 Communication Control System Installation and Configuration 025 9533Y...
Page 6: ...6 025 9533Y...
Page 28: ...Introduction 28 025 9533Y...
Page 88: ...Common Control Equipment Installation 88 025 9533Y Figure 22 Console Duplex Wall Jacks...
Page 110: ...Common Control Equipment Installation 110 025 9533Y...
Page 172: ...Console Installation 172 025 9533Y...
Page 192: ...Audio Level Adjustments 192 025 9533Y...
Page 230: ...Accessory Installation 230 025 9533Y...
Page 236: ...Console ANI Programming 236 025 9533Y...
Page 339: ...339 RSMP Operation Figure 99 Main Screen...
Page 350: ...Radio System Management Program 350 025 9533Y...
Page 362: ...Appendix B Troubleshooting 362 025 9533Y...
Page 418: ...Index 418 025 9533Y...