The
Update
selection can be used to update the associated file with that stored in the
alternate location. For example, if the administration of the configuration is performed on
a network file directory it would be desirable to copy that centrally located file to the local
PC hard disk to synchronize the configurations between the primary and secondary file
locations. Conversely, if changes are made to the configuration stored locally on the PC, it
may be necessary to update the network files.
Selecting
Update
for the
Primary file
copies the Secondary file to the Primary file
location. Selecting
Update
for the
Secondary file
copies the Primary file to the Secondary
file location.
The Configuration Number entry identifies the actual configuration within the
configuration file for this position. Typically, this is set to “1” for all positions unless there
are differences in the screen configuration (excluding the channel layout) from one
position to the next.
When using with Zetron's User Management System, the logged-on user must have the
UMS IntegratorRD change settings and configuration permission to store any changes.
Upgrading the Configuration File
To upgrade the configuration file to be used in a newer version IntegratorRD
1. Open the file with the new version RDPS.
2. Follow any instruction prompts there may be for upgrading your configuration.
3. Save the configuration file.
4. In IntegratorRD, reload the new configuration file by restarting the application or
right-clicking in the title bar and selecting
Reload Configuration
.
Caution!
Certain features, such as MDC-1200, Priority Transmit, and
takeover functions, are managed system-wide by console 1.
Therefore, in a new system, it is important to configure and
start console 1 before testing the other consoles. Console 1 is
not determined by physical location or any labelling made on-
site. Console 1 is the console connected by serial cable to the
first CIC card.
!
Caution!
When upgrading an existing configuration, Zetron
recommends that Console 1 is upgraded last. This helps to
resolve problems prior to working on Console 1, which can
impact normal operation of the entire system.
!
Summary of Contents for 4000 Series
Page 1: ...Series 4000 Communication Control System Installation and Configuration 025 9533Y...
Page 6: ...6 025 9533Y...
Page 28: ...Introduction 28 025 9533Y...
Page 88: ...Common Control Equipment Installation 88 025 9533Y Figure 22 Console Duplex Wall Jacks...
Page 110: ...Common Control Equipment Installation 110 025 9533Y...
Page 172: ...Console Installation 172 025 9533Y...
Page 192: ...Audio Level Adjustments 192 025 9533Y...
Page 230: ...Accessory Installation 230 025 9533Y...
Page 236: ...Console ANI Programming 236 025 9533Y...
Page 339: ...339 RSMP Operation Figure 99 Main Screen...
Page 350: ...Radio System Management Program 350 025 9533Y...
Page 362: ...Appendix B Troubleshooting 362 025 9533Y...
Page 418: ...Index 418 025 9533Y...