IntegratorRDPS Programming
324
Setting iDEN Call Capcodes
Instant call buttons may be used to setup calls and send statuses or call alerts to iDEN
radios. (Details are shown below.)
The valid entries for iDEN instant call pages are:
Setup private call:
<leading digit><radio id>#
For example: 3543#
Setup target call:
<leading digit><radio id>#T
For example: 312#T
Setup group call:
<leading digit><radio id>#G
For example: 32#G
Send status call:
<leading digit><radio id>S<status number>
Status number ranges from 1 to 255. For example: 3123S244
Send call alert:
<leading digit><radio id>C
For example: 3123C
Setting the Paging Channels
For Select-then-Transmit and Instant Transmit page types, a list of channels is available to
be checked for steering the page to the appropriate channel. For multiple-frequency
channel types, you may also specify a frequency select number (in the range 1 to 8).
Setting the Inter-page Stack Delay
Under certain circumstances, it may be necessary to increase the amount of time delay
between each page sent in a stacked page. Use the scroll bar to select the stack delay.
Enabling the Voice Message Prompt
By specifying a time for the Voice Message, the console holds the transmit active for the
specified amount of time following the completion of the page.
In rare circumstances when using DC channels, a busy transmit failure can occur if the
user keys up very soon after a page. Adding the appropriate amount of Voice Message
time (2 seconds for example) prevents this failure.
Note
Examples are leading digit 3.
Summary of Contents for 4000 Series
Page 1: ...Series 4000 Communication Control System Installation and Configuration 025 9533Y...
Page 6: ...6 025 9533Y...
Page 28: ...Introduction 28 025 9533Y...
Page 88: ...Common Control Equipment Installation 88 025 9533Y Figure 22 Console Duplex Wall Jacks...
Page 110: ...Common Control Equipment Installation 110 025 9533Y...
Page 172: ...Console Installation 172 025 9533Y...
Page 192: ...Audio Level Adjustments 192 025 9533Y...
Page 230: ...Accessory Installation 230 025 9533Y...
Page 236: ...Console ANI Programming 236 025 9533Y...
Page 339: ...339 RSMP Operation Figure 99 Main Screen...
Page 350: ...Radio System Management Program 350 025 9533Y...
Page 362: ...Appendix B Troubleshooting 362 025 9533Y...
Page 418: ...Index 418 025 9533Y...