Common Control Equipment Installation
40
Figure 11: Central “Star” Grounding System
Do not connect signal ground to the central “star” ground. The conditioning and reference of the
signal grounds is controlled inside the Zetron equipment. The system will be more susceptible to
noise interference.
Copper or Aluminum
Ground Plates
Ground Wires
#14 AWG or Larger
EARTH GROUND
#0 AWG or Larger
Series 4000
Common
Control
Common
Control
Units
CRT
M4217B
PC
TRHI
Model
4018
Desktop
Dispatch
Consoles
Model
4118
Model
4115
Headset
Jack
Rack-Mount
Dispatch
Consoles
Protected
Punch-down
Block
Radio
A
Radio
B
Phone
Interface
PBX/CO