Chapter 3
GSM Asynchronous Mode Operation
Burst analyzer
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
135
Burst analyzer
To gain access to this menu, push the [Analyzer Burst] marker tab while working
with the generator/analyzer tool.
This menu displays the results of the asynchronous burst measurements of the
RF signal received at the
Using the burst analyzer
The RF analyzer takes measurements in asynchronous mode, without any call
processing functions.
Any
“Coupling loss”
table defined in the appropriate menu will be used for asyn-
chronous measurements as well.
Before starting a measurement, the radio frequency to be measured on has to be
entered.
There are entry fields available for these parameters in the lower area of the
menu, just above the softkeys.
The
and the display markers are similar to the corre-
sponding areas and fields of the standard GSM test menu.
Parameter fields of the
burst analyzer
The radio frequency to measure on and the trigger functions are set in this menu
area.
NOTE
The analyzer will measure the signal and display the results assuming that the
signal is GMSK-modulated if the 4400 generator is set to GMSK as well. If the
generator of the 4400 is set to transmit an unmodulated signal, the measure-
ments in the analyzer are calculated assuming that the signal at the RF input
connector is unmodulated as well.