Appendix A
SCPI Command Reference
MEASure subsystem
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
511
:MEASure:EGPRs[:CONTinuous]:RFTX:EPEAk
:MEASure:EGPRs[:CONTinuous]:RFTX:ENFTh
:MEASure:EGPRs[:CONTinuous]:RFTX:EOFFset
Syntax
:MEASure:EGPRs[:CONTinuous]:RFTX:EPEAk
Parameters
There are no parameters.
Description
Starts a continuous measurement of the maximum error vector magnitude within a
burst. EVM is indicated per cent. To read out the measurement results, use the
:FETCh:EGPRs:RFTX:EPEAk
command.
Query
The query form of this command will start the measurement and return a measure-
ment result value as soon as the first measurement has been completed. The string
delivered back will contain one floating point real number with the physical dimen-
sion of %.
Example
:MEAS:EGPRs:RFTX:EPEAk?
The maximum error vector magnitude measurement will be performed and the result
will be returned. Example of the returned string:
"6.33".
Syntax
:MEASure:EGPRs[:CONTinuous]:RFTX:ENFTh
Parameters
There are no parameters.
Description
Starts a continuous measurement of the error vector magnitude that is not exceede
by 95% of the symbols of a burst. The 95% EVM is shown in %. To read out the mea-
surement results, use the
:FETCh:EGPRs:RFTX:ENFTh
command.
Query
The query form of this command will start the measurement and return a measure-
ment result value as soon as the first measurement has been completed. The string
delivered back will contain one floating point real number with the physical dimen-
sion of %.
Example
:MEAS:EGPRs:RFTX:ENFTh
:FETC:EGPRs:RFTX:ENFTh?
The maximum error vector magnitude measurement will be performed. The measure-
ment result will be stored internally and read by the
FETC
command. An example of
the string returned is: "
4.33
".
Syntax
:MEASure:EGPRs[:CONTinuous]:RFTX:EOFFset
Parameters
There are no parameters.
Description
Starts a continuous measurement of the origin offset. The origin offset indicates the
accuracy of the i/Q modulators DC setup; it is usually an undesire leakage produced
due to a DC offset in the phones I/Q modulator. It is measured in dBc. To read out the
measurement results, use the
:FETCh:EGPRs:RFTX:ENFTh
command.
Query
The query form of this command will start the measurement and return a measure-
ment result value as soon as the first measurement has been completed. The string
delivered back will contain one floating point real number with the physical dimen-
sion of dBc.