Appendix A
SCPI Command Reference
CALCulate Subsystem
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
629
:CALCulate:GSM:RFTX:TEMPlate:RACH:LIMit:AUTO
:CALCulate:GSM:RFTX:TEMPlate:RACH:LIMit:STATe
:CALCulate:GSM
:RFTX:TEMPlate:RACH:LIMit:UPPer[:DATA]
Syntax
:CALCulate:GSM:RFTX:TEMPlate:RACH:LIMit:AUTO <Pre-
defExp>
Parameters
PredefExp
is one of the following predefined expressions:
ON|OFF
. Default is
ON
.
Description
This command selects the power/time template to check a random access burst
against.
Auto mode
(parameter
ON
) means that the Willtek 4400 will use the appropriate PTT
as defined in the GSM/ETSI standards. Those PTTs vary with the frequency range and
the RF power level used by the mobile.
Manual mode
(parameter
OFF
) means that the GSM/ETSI specifications will be
ignored and that the Willtek 4400 will use the manually set limits instead (see
description of the
:CALC:GSM:RFTX:TEMP:RACH:LIM:UPP
and
:CALC:GSM:RFTX:TEMP:RACH:LIM:LOW
commands for further details).
Query
There is on query form to this commmand.
Example
:CALC:GSM:RFTX:TEMP:RACH:LIM:AUTO ON
Switches the limit check for the shape of
random access
bursts to use the standard
PTTs as defined by GSM/ETSI.
Syntax
:CALCulate:GSM:RFTX:TEMPlate:RACH:LIMit:STATe <Pre-
defExp>
Parameters
PredefExp
is one of the following predefined expressions:
ON|OFF
. Default is
ON
.
Description
This command switches the limit check of the burst shape against the PTT (of random
access bursts) either on or off.
Query
There is no query form of this command available.
Example
:CALC:GSM:RFTX:TEMP:RACH:LIM:STAT ON
Switches on the limit check of the shape of
random access
bursts against the PTT.
Syntax
:CALC:GSM
:RFTX:TEMPlate:RACH:LIMit:UPPer[:DATA]
<real0t>,<real0p>,<real1t>,<real1p>,
<real2t>,<real2p>,<real3t>,<real3p>,
<real4t>,<real4p>,<real5t>,<real5p>,
<real6t>,<real6p>,<real7t>,<real7p>, <real8t>,<real8p>