Chapter 2
GSM Call Mode Operation
System parameters
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
109
Corner points
On this menu, you may set eight points for checking critical burst positions.
Those positions are defined by a time relative to the start of the burst, a minimum
and a maximum RF power level.
The eight critical burst positions are shown graphically in the lower area of this
menu. If burst measurements have been obtained, those positions will be shown
in relation to the burst as in the example below.
The current measurement results for those eight corner points are displayed in
the
“Burst test menu”
.
All measurement results obtained for a burst test have to be within the limits as
entered on this menu in order to make the entire burst test PASS.
If a single corner point limit in only one of all bursts measured is violated, the
whole burst test will be marked as FAIL.
NOTE
Separate limits and defaults exist for GSM 1800 and GSM 1900. If the
selected upper band is GSM 1800, the limits for this band apppear; if the
upper band is GSM 1900, the respective limits for this band are shown. The
upper frequency band can be changed on the
“Basic system parameters”
screen.
NOTE
This menu bears a great saving in test time when used together with the
remote control of the 4400. Using the corresponding SCPI commands, you
may set the corner points remotely and read out the test results for those
eight critical positions with one single command.