Appendix A
SCPI Command Reference
MEASure subsystem
476
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
:MEASure[:GSM][:CONTinuous]:RFRX:BER:CRC
:MEASure:GSM[:CONTinuous]:RFRX:FBER
Query
The query form of this command will start the measurement and return a measure-
ment result value as soon as the first measurement has been completed. The string
delivered back will contain one floating point real number, representing the bit error
ratio.
Example
:MEAS:GSM:CONT:RFRX:BER:CII?
Measurement result string delivered back:
"0.2"
.
Syntax
:MEASure:GSM[:CONTinuous]:RFRX:FBER
Parameters
There are no parameters.
Description
Starts a continuous measurement of the (non-residual) bit error ratio on the class II
bits. To read out the latest measurement result, use the
:FETCh:GSM:RFRX:BER:CII
command.
Notes
–
More details regarding BER testing can be found in section BER Live Display.
–
More details regarding bit classes can be found in section Voice Coding.
–
The number of samples to be used for testing can be set, using the
:CONF:GSM:BER:COUNt
command.
Query
The query form of this command will start the measurement and return a measure-
ment result value as soon as the first measurement has been completed. The string
delivered back will contain one floating point real number, representing the bit error
ratio.
Example
:MEAS:GSM:RFRX:BER:CRC?
Measurement result string delivered back in this example:
"0.2"
.
Syntax
:MEASure:GSM[:CONTinuous]:RFRX:FBER
Parameters
There are no parameters.
Description
Starts a continuous measurement of the fast bit error ratio (C-type loop). To read out
the latest measurement result, use the
:FETCh:GSM:RFRX:FBER
command.
Notes:
–
More details regarding Fast BER testing can be found in section BER Live Display.
–
The number of samples to be used for testing can be set, using the
:CONF:GSM:BER:COUNt
command.
Query
The query form of this command will start the measurement and return a measure-
ment result value as soon as the first measurement has been completed. The string
delivered back will contain one floating point real number, representing the bit error
ratio.
Example
:MEAS:GSM:CONT:RFRX:FBER?
Measurement result string delivered back:
"1.5"
.