Chapter 5
EDGE Asynchronous Mode Operation
Burst analyzer
188
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
Softkeys of the RF
Analyzer
Result fields
For basic information on results provided on the EVM/Frequency menu, see
. The results displayed on the EVM/Frequency menu
apply to the slot set by the input parameter Results for UL Slot.
The EVM/Frequency display shows the test results and statistical values for
various modulation quality parameters. The parameters are:
– Level – the RF power level received by the 4400 (in dBm)
– RMS EVM – the error vector magnitude rms-averaged over a burst. EVM is a
relative value and shown as a percentage.
– Peak EVM – the maximum error vector magnitude within a burst. EVM is
indicated in per cent.
– 95th% EVM – the error vector magnitude that is not exceeded by 95% of
the symbols of a burst. The 95th% EVM is shown in %.
– Frequency Error – the deviation of the carrier frequency compared to the
expected carrier. The frequency error is measured in Hertz. The measurement
accuracy depends on the time base used (internal TCXO, OCXO or an external
reference).
– Origin Offset – The origin offset indicates the accuracy of the I/Q modu-
lator’s DC setup; it is usually an undesired leakage produced due to a DC
offset in the phone’s I/Q modulator. It is measured in dBc.
Burst analyzer
To gain access to this menu, push the [Analyzer Burst] marker tab while working
with the generator/analyzer tool.
This menu displays the results of the asynchronous burst measurements of the
RF signal received at the RF in/out connector.
This softkey leads you to the parameter screens where you
can set up limits.
A push on this softkey switches the
either on or
off.
To freeze the current display for further or detailed analysis
(or for printing), push this softkey.
The softkey will change to
Unfreeze
.
Note:
After the
Freeze
softkey has been pushed, all mea-
surements will continue in the background, but the display
will not be updated.
A push on this softkey resets the statistic evaluation of the
measurement results. The measurement counter will be reset
as well.