Appendix A
SCPI Command Reference
MEASure subsystem
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
571
:MEASure:EGPRs:ARRay:RFTX:ENFTh
:MEASure:EGPRs:ARRay:RFTX:EOFFset
Syntax
:MEASure:EGPRs:ARRay:RFTX:ENFTh <int1>
Parameters
<int1>
is an integer.
The minimum value for
<int1>
is
0
, the maximum value is
100
. The default value
for
<int1>
is
0
.
Description
Measures multiple times (set with the
<int1>
parameter) the error vector magni-
tude that is not exceeded by 95% of the symbols of a burst. The 95% EVM is shown
in %. To read out the entire measurement results array, use the
:FETCh:EGPRs:RFTX:ENFTh
command.
Query
The query form of this command returns a string, containing
<int1>
floating point
real numbers with the physical dimension of %, representing the measurement
results.
The single measurement results are separated by commas.
Example
:MEAS:EGPRs:ARR:RFTX:ENFTh 5
:FETC:EGPRs:RFTX:ENFTh?
The maximum error vector magnitude measurement will be performed five times. The
measurement results will be stored internally and read by the
FETC
command. An
example of the string returned is: "
4.33,5.53,1.97,3.41,2.79
".
Syntax
:MEASure:EGPRs:ARRay:RFTX:EOFFset <int1>
Parameters
int1
is an integer.
The minimum value for
int1
is
0
, the maximum value is
100
. The default value for
int1
is
0
.
Description
Measures multiple times (set with the
int1
parameter) the Origin Offset. The origin
offset indicates the accuracy of the i/Q modulators DC setup; it is usually an undesire
leakage produced due to a DC offset in the phones I/Q modulator. It is measured in
dBc. To read out the entire measurement results array, use the
:FETCh:EGPRs:RFTX:ENFTh
command.
Query
The query form of this command returns a string, containing
int1
floating point real
numbers with the physical dimension of dBc, representing the measurement results.
<BR>The single measurement results are separated by commas.
Example
:MEAS:EGPRs:ARR:RFTX:EOFFset 5
:FETC:EGPRs:RFTX:EOFFset?
The maximum error vector magnitude measurement will be performed five times. The
measurement results will be stored internally and read by the
FETC
command. An
example of the string returned is: "
4.33,5.53,1.97,3.41,2.79
".