Appendix A
SCPI Command Reference
CONFigure subsystem
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
413
:CONFigure:GSM:MSLot
:CONFigure:GSM:ASSAll
Description
Selects the type of GSM system to be used after the Willtek 4400 was brought into
GSM call mode.
GSM9001800
will make the Willtek 4400 work as a test set for the GSM system
types GSM 900 and GSM 1800.
GSM9001900
will set up the Willtek 4400 as a test set for the GSM system types
GSM 900 and GSM 1900.
Notes
–
This command will have no effect when the Willtek 4400 is in generator/analyzer
mode.
–
The main reason for this command to exist is the 'double numbering' of channels.
GSM 1800 and GSM 1900 use the same channel numbers above channel number
511, but the related physical channels are in different frequency bands.
Query
The query form of this command will return the current setting. The string delivered
back will contain one of the predefined expressions as explained above.
Example
:CONFigure:GSM:TYPE GSM9001900
:CONF:GSM:TYPE?
Value returned:
"GSM9001900"
.
Syntax
:CONFigure:GSM:MSLot <PredefExp>
Parameters
PredefExp
is one of the following predefined expressions:
ON|OFF
.
Default is
OFF
.
Description
Turns multislot operation either on or off.
OFF
means that standard GSM is active
and all multislot functions are disabled.
Note:
HSCSD or multislot testing requires the Multislot Option to be installed on your
Willtek 4400.
Query
The query form of this command will return the current setting. The string delivered
back will contain one of the predefined expressions as explained above.
Example
:CONFigure:GSM:MSLot ON
:CONF:GSM:MSL?
Value returned:
"ON"
.
Syntax
:CONFigure:GSM:ASSAll <int1>,<int2>
Parameters
int1
and
int2
are two integers.
The minimum value for
int1
is
0
, the maximum value is
1023
. The default value for
int1
is
45
.
The minimum value for
int2
is
0
, the maximum value is
31
. The default value for
int2
is
10
.
Description
This command changes the TCH (traffic channel) number and the mobile's power con-
trol level in one assignment.
int1
is the new TCH channel number and
int2
is the MS power control level.
Note:
The RF power control level is a code. The corresponding RF output power of the
mobile under test depends on the type of GSM system and the frequency range. For
details, please refer to section
“Power control levels and tolerances” on page 115
.