Appendix A
SCPI Command Reference
CONFigure subsystem
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
427
:CONFigure:GSM:MEASure:ACPM:TRANsient
Description
This command allows to set a user-specific sequence of power supply tests on the
Willtek 4400. The sequence has to be started with the appropriate commands of the
MEASure
subsystem (
:MEAS:CONT:PSUP:GROU
or
:MEAS:ARR:PSUP:GROU
).
The meaning of the parameters is as follows:
CAVG
stands for the average current drawn by the mobile,
while
CPEak
is the peak current drawn by the mobile over the defined measurement
period. The defined measurement period can be set using the command
:PSUP:MEAS:DURA
. Please refer to section
“MS Power Supply subsystem” on
page 803
for further details.
PAVG
is the average power requirement of the mobile under test.
Notes
–
This command must be used with at least one parameter specified. All other
parameters are optional.
–
Unless organized in this sequence, the start of a new power supply test will
always terminate the preceding one instantly. Therefore, this command is an effi-
cient way to perform several power supply measurements in a sequence.
–
Please note that any power supply test command will need the power supply
option to be installed on your Willtek 4400 (see section Accessories for details).
–
Further details regarding the tests can be found in section
“MEASure subsystem”
on page 461
.
Query
The query form of this command will return the current sequence of power supply
tests to be performed by the Willtek 4400. The string delivered back will contain a
maximum of three short-form versions of the predefined expressions explained
above.
Example
:CONFigure:MEASure:GROUp:PSUPply CPEak,PAVG
:CONF:MEAS:GROU:PSUP?
Value returned:
"CPE,PAVG"
Syntax
:CONFigure:GSM:MEASure:ACPM:TRANsient <PredefExp>
Parameters
PredefExp
is one of the following predefined expressions:
EDGes|FULL
.
Default is
EDGes
.
Description
Selects the time period over which the Willtek 4400 calculates the RF output spec-
trum due to switching transients (or ACP Transient for short).
If
FULL
is selected, the Willtek 4400 will perform the measurement over the whole
burst (including the edges); this is in line with the ETSI specifications.
With
EDGes
, measurements are performed over the leading and trailing edges of the
burst only, ignoring any spectral impact of the modulation (active part of the burst).
The latter measurement takes less time and hence leads to faster measurements.
Query
The query form of this command will return the current setting. The string delivered
back will contain the short-form version of one of the predefined expressions
explained above.
Example
:CONF:GSM:MEASure:ACPM:TRAN FULL
:CONF:GSM:MEASure:ACPM:TRAN?
In this example, the query will return the string
FULL
.