![Watkiss DigiVAC Service Manual Download Page 15](http://html1.mh-extra.com/html/watkiss/digivac/digivac_service-manual_3694152015.webp)
Overview
•
Fuses
Watkiss DigiVAC Service Manual - Issue 2 - 29/11/04
9
FUSE
SYMPTOMS OF FAILURE
DigiVAC Standard
Mains input socket
No mains switch illumination
No mains switch illumination
Machine Dead
Machine Dead
DigiVAC Base PCB F1 Control Panel Dead
Control Panel Dead
Transformer LED on
Transformer LED on
Machine Dead
Machine Dead
DigiVAC Base PCB F2 Machine will start, but no
feed occurs showing up on
the bin as a Jam
‘PSU VOLTAGE ERROR: 28v’
message is displayed
No Jog or Oscillate Function
is available
DigiVAC Base Power
PCB F4
No Jog function
‘No Power to Stacker’ mes-
sage displayed
No Oscillate function selecta-
ble from the panel
XJOG Mimic shows yellow
DigiVAC Base Power
PCB F5
Motor Stalled Error
Motor Stalled Error
X-Jogger PCB F1
No Oscillate function
‘No Power to Stacker’ mes-
sage displayed
XJOG Mimic shows yellow
Transformer
Mains switch is illuminated
Mains switch is illuminated
LED on the transformer is
not illuminated
LED on the transformer is
not illuminated
Machine Dead
Machine Dead