Chapter 8 Ethernet coupler
Manual VIPA System 200V
8-8
HB97E - IM - Rev. 06/29
A twisted pair network can only be constructed with a star topology.
Hub/
Switch
Hub/
Switch
Mini-Switch CM 240
Twisted Pair Cable
CM 240
S
A
C
S
A
C
S
A
C
S
A
C
+
X 2
3 4
-
G
D
C
5-
24
V
opt. In
A Twisted Pair cable is a cable with four cores
drilled in pairs.
The single cores have a diameter of 0.4 to 0.6mm.
This is a summary of the restrictions and rules referring to Twisted Pair:
•
Maximum number of coupler elements per segment
2
•
Maximum length of a segment
100m
•
What is the size of the area that must be served by the network?
•
How many network segments provide the best solution for the physical
(space, interference related) conditions encountered on site?
•
How many network stations (SPS, IPC, PC, transceiver, bridges if
required) must be connected to the cable?
•
What is the distance between the different stations on the network?
•
What is the expected ”growth rate” and the expected number of
connections that must be catered for by the system?
•
What is the expected data amount (Band width, accesses/sec.)?
•
Draw a diagram of the network. Identify every hardware item (i.e. station
cable, Hub, switch). Observe the applicable rules and restrictions.
•
Measure the distance between all components to ensure that the
maximum length is not exceeded.
Overview
components
Restrictions
Analyzing the
requirements
Drawing a
network diagram
Summary of Contents for System 200V IM Series
Page 1: ...Manual VIPA System 200V IM Order No VIPA HB97E_IM Rev 06 29...
Page 2: ...Lerrzeichen...
Page 6: ...About this manual Manual VIPA System 200V Subject to change to cater for technical progress...
Page 10: ...Contents Manual VIPA System 200V iv HB97E IM Rev 06 29...
Page 18: ...Chapter 1 Basics Manual VIPA System 200V 1 6 HB97E IM Rev 06 29...
Page 136: ...Chapter 3 Profibus DP Manual VIPA System 200V 3 104 HB97E IM Rev 06 29...
Page 338: ...Chapter 8 Ethernet coupler Manual VIPA System 200V 8 34 HB97E IM Rev 06 29...
Page 344: ...Chapter 9 Bus expansion modules IM 260 IM 261 Manual VIPA System 200V 9 6 HB97E IM Rev 06 29...