Application functions
199
Byte
Control bit
Functions
Bit 9
Dynamic brake is ON after motor stopped due to fault group1
Bit 10
Dynamic brake is ON after motor stopped due to fault group2
Bit 11
Dynamic brake is ON after motor stopped due to fault group3
Bit 12
Dynamic brake is ON after motor stopped due to fault group4
Bit 13
Dynamic brake is ON after motor stopped due to fault group5
Bit 14
Dynamic brake is ON after motor stopped due to fault group6
Bit 15
Dynamic brake is ON after motor stopped due to fault group7
The relevant parameters of [dynamic braking] for motor stop are as follows.
Index
Name
Unit
Setting range
Default value
effective
Period
0x2195
Fault Reaction Stop Option0
—
0-0x00070007
0
Restart
Y
0x2196
Fault Reaction Stop Option1
—
0-0x00070007
0x00000004
Restart
Y
0x2197
Fault Reaction Stop Option2
—
0-0x00070007
0x00000203
Restart
Y
0x2198
Fault Reaction Stop Option3
—
0-0x00070007
0x00000302
Restart
Y
0x2199
Fault Reaction Stop Option4
—
0-0x00070007
0x00000400
Restart
Y
0x219A
Fault Reaction Stop Option5
—
0-0x00070007
0x00000501
Restart
Y
0x219B
Fault Reaction Stop Option6
—
0-0x00070007
0x00000603
Restart
Y
0x219C
Fault Reaction Stop Option7
—
0-0x00070007
0x00000701
Restart
Y
0x219E
Hardware Limit Switch Stop
Option Code
—
0-0x000000FF
0
Immediately
Y
0x605A
Quick stop option code
—
0-0x00FF
0x0002
Immediately
Y
0x605B
Shutdown option code
—
0-0x00FF
0x0001
Immediately
Y
0x605C
Disable operation option code
—
0-0x00FF
0x0001
Immediately
Y
0x21A0
STO Option Code
—
0-0x00030307
0
Restart
Y
By setting the corresponding bytes of the above parameters, the [dynamic braking] mode can be used for
motor stop. The specific operations are as follows:
1.
For each [fault stop option], its Byte0 can be set to 0x00: Disable drive function, and the motor stops
with dynamic brake ON.
2.
For [STO action option code], its Byte0 can be set to 0x01: Disable drive function, and the motor
stops with dynamic brake ON.
3.
For other [option codes], their Byte0 can be set to 0xFF: Disable drive function, and the motor stops
with dynamic brake ON.
How to use
8.8.3
The method for using dynamic braking is as follows.
1.
If a motor needs to stop in the mode of [dynamic braking], its stop mode can be set as [dynamic braking for stop] in the
corresponding fault option or stop option code as described above.