Settings
107
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x21B2
0
EtherCAT Alias Name
-
0~4294967295
6
Restart
Y
CiA402 Setting
4.11
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x21D6
0
CiA402 setting 1
-
0~0x11010303
0
Restart
Y
Byte0: Definition of status word 0x6041.bit15
0x00-Reserved;
0x01-Motor rotation state (1= rotating);
0x02-Alarm detecting state (1=alarm detected);
0x03- Homed state (1= homed);
0x04-STO status(1=STO).
Byte1: Definition of status word 0x6041.bit14
0x00-Reserved;
0x01-Motor rotation state (1= rotating);
0x02-Alarm detecting state (1=alarm detected);
0x03- Homed state (1= homed);
0x04-STO status(1=STO).
Byte2: Object 0x6061 update timing selection
0x00- Consistent with object 0x6060;
0x01 - Consistent with the actual control mode.
Byte2: Enter into ready to switch on state automatically switch
0x00-Disable;
0x01-Enable
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x21D9
0
CiA402 setting 2
-
0~0x03030303
0
Restart
Y
Byte0: Definition of control word 0x6040.Bit12
0x00-Reserved;
0x01-Clear multi-turn value of position encoder (rising edge);
0x02-Configure position encoder (rising edge);
0x03-Clear fault of position encoder (rising edge).
Byte1: Definition of control word 0x6040.Bit13
0x00-Reserved;
0x01-Clear multi-turn value of position encoder (rising edge);