Running
115
3.
There is no need to modify the default settings. Click the [Start] button.
If the detection is unsuccessful, properly adjust parameters such as the magnetic pole phase angle
detection current, magnetic pole phase angle phase sequence current, and magnetic pole phase angle's
phase sequence detection threshold. When you need to detect the phase sequence, select the magnetic
pole phase angle phase sequence detection switch as "1: enable phase sequence detection".
4.
When the static detection is complete, you will be prompted that the execution process is complete and the results are
successful. Click the [Save] button.
5.
You will be prompted that the static method information was saved successfully, and click the [OK] button.
6.
When the drive is powered on again, the motor magnetic polar phase angle parameter takes effect.
Summary of Contents for CoolDrive Series