Monitoring
222
Debugging software monitoring - data trace
9.2.7
[Data trace] is used to grab the waveform of trace variables according to given trigger conditions.
Click the [Data trace] button in the shortcut button bar of the main interface of the debugging software, and the "data
trace" window will be opened, as shown in the figure below.
Configure
information
Data trace display
Sampling
settings
Variable
tracing
settings
Trigger
settings
Sampling
and saving
The functions of each part are as follows.
[Configure information]: used to save sampling settings as a fixed scheme for direct call in the future;
[Sampling settings]: used to set such information as channel number, sampling
points
and sampling
cycle
;
[Variable tracing settings]: used to set the traced variables corresponding to each channel;
[Trigger settings]: used to set such trigger conditions as trigger source, trigger mode and trigger level;
[Sampling and saving]: used to configure sampling options, starting sampling and saving waveform files;
[Data trace display] interface: used to show data waveforms collected by each channel.
Sampling settings
Before data trace, the sampling parameters shall be set according to the number of variables and the wave properties.
[
Number of Channels
] is used to set the number of channels to be used, which can be selected from the drop-down menu.
Up to 8 channels are supported;
[Sampling
points
] is used to set the total number of samples of a single channel, which can be selected from the
drop-down menu. The maximum
Number of sampling points is
8192;
Summary of Contents for CoolDrive Series
Page 29: ...Preface 17 T2 model ...
Page 30: ...Preface 18 T3 model ...
Page 31: ...Preface 19 T4 model ...
Page 230: ...Monitoring 218 ...