Settings
62
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x213A
0
Drive
Overload
Derating factor
%
10~100
100
Restart
Y
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x213B
0
DC Bus UnderVoltage
Detect Time
ms
1~10000
50
Immediate
ly
Y
Set the drive DC bus under-voltage fault detection time.
When the actual value of DC bus voltage is lower than 0x2136 and the duration exceeds this set value, the DC bus
undervoltage alarm occurs.
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x21CC
0
DC Bus Steady Voltage
mV
0~65535
2000
Restart
Y
When the fluctuation of DC bus voltage is less than the set value of this parameter, the DC bus is considered to be charged
OK.
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x21ED
0
External Regeneration
Resistor
Overload
Protection Threshold
%
100~65535
1000
Restart
Y
Set the allowable overload multiples of the external energy consumption braking resistor.
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x21EE
0
External Regeneration
Resistor
Overload
Protection Time
ms
100~65535
5000
Restart
Y
Set the allowable overload time of the external energy consumption braking resistor.
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x21F6
0
Regeneration Resistor
Thermal Time Constant
sec
120
5000
Restart
Y