![Tsino Dynatron CoolDrive Series User Manual Download Page 81](http://html.mh-extra.com/html/tsino-dynatron/cooldrive-series/cooldrive-series_user-manual_1178327081.webp)
Settings
69
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
stronger the overload capacity of the motor is.
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x205B
0
Max
Motor
Torque
under Max Speed
‰
1000~10000
3000
Restart
Y
Set the maximum torque at the maximum speed of the motor.
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x205C
0
Max Motor Speed under
Max Torque
rev/min
100~20000
5000
Restart
Y
Set the maximum speed at the maximum torque of the motor.
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x205D
0
Motor
Tooth-Slot
Number
-
1~100
10
Restart
Y
Set the number of motor coggings.
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x2083
0
Motor Overheat protect
Thermocouple
Resistance Value
Ohm
0~2147483647
0
Restart
Y
Set the motor overheating protection threshold value.
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x21E5
0
Motor Torque Constant
Nm/
mArms
0~2147483647
0
Restart
Y
Set the motor torque constant.
If the exact value of this parameter cannot be obtained, set to zero. In this case, the drive considers the motor torque
constant = motor rated torque /motor rated current.
This parameter is related to the rated torque of the motor [0x6076] and the rated current of the motor [0x6075]. Under
normal circumstances, the motor torque constant
≈
motor rated torque /motor rated current. If NOT, please reconfirm