I-14
Table 2-1; Connection Terminals
Specification or settings may limit the functions.
Please be careful of the polari/-) of each line.
Name
Connection
Instruction
Relay Output
CH1
CH2
CH3
CH4
(*1)
TB3
TB4
TB5
TB6
"+" is for positive-side and "-" is for negative-side of Voltage or current source.
User can assign max 4 types of contact output from following selection.
(1)BREAK: Not Used (Normal Open)
(2)MAKE: Not Used (Normal Close)
INTG PULSE
:
Totalizing Pulse output
(3) FW INTG
:
One pulse for every totalizing unit of forward flow.
(4) BW INTG
:
One pulse for every totalizing unit of backward flow.
Output pulse width is selectable.
(5) ROFF: Receiving Echo Error Alarm
(contact closes under alarm condition)
(6) B.D.
:
Break Down (unit failure)
Alarm (contact closes under alarm condition)
(7) B.D.or ROFF
:
Contact closes
under alarm condition (5) or (6)
LIMIT
:
High or Low limit alarm
(8) HI-LMT
:
Contact closes when measuring value exceeds the limit
(9) LO-LMT
:
Contact closes when measuring value falls below the limit
Polarization is ignored for this limitation alarm.
DRCT
:
Direction output
(10) FW-DRCT: Contact closes
for
Forward flow.
(11) BW-DRCT
:
Contact closes
for
Backward flow.
RANGE
:
Analog Range selector output for double range output
(12) HI-RNG
:
Contact closes for high range values.
(13) LO-RNG
:
Contact closes for low range values.
ANALOG OUT
1, 2
TB8
TB9
Analog Output
"1+" and "1-" mean channel 1.
"2+" and "2-" mean channel 2.
"+" is current source side and "-" is current sink side.
Power
Source
(*2)
TB1
When main unit type is for AC Power supply, "N" should be connected to
Neutral-line and "L" should be connected to Live-line.
When main unit type is for DC Power supply, "+" should be connected to
Positive-line and "-" should be connected to Negative-line.
Protective
Earth
PE terminal
PE terminal .should be connected to earth of power source.
Path-1
UP
DN
TB10-(1 )
TB10-(4)
Connect upstream transducers to "UP" side.
Connect to downstream transducers to "DN" side.
Connection to primary path Transducers when 2 path measurement.
(*3)
Path-2
UP
DN
TB11-(1 )
TB11-(4)
Connection to secondary path Transducers when 2 path measurement.
(*3)
Connect upstream transducers to "UP" side.
Connect to downstream transducers to "DN" side.
Mult-path
Junction
box
(*4)
Path1: J3/J4
Path2: J6/J7
Path3: J9/J10
Path4: J12/J13
Cables from Multi-path junction box are connected to them.
Multi-path junction box (option) is used for transducer connection when 4 path
measurement.
DIGITAL
1,2 (*5)
RJ-45
RS232C output.
(*1) Independent settings are provided for contact outputs of each channel (CH1-CH4).
Please refer to details in "Chapter II-1 Function" and "Chapter II-2 Operation"
(*2) Type of AC or DC power supply can be selected before shipment.
Specified cable should be used for power cable to comply with EC directive.
(*3) 2 path measurement system is an option.
(*4) 4 path measurement system involves special connection. 4-path measurement is an option.
(*5) Length of DIGITAL output cable should be less than 3 m long to comply with EC directive.
Summary of Contents for UFL-30
Page 1: ...Doc No KF08 001J Ultrasonic Flowmeter UFL 30 Installation Operation Manual ...
Page 11: ... 10 blank ...
Page 12: ...I Installation ...
Page 60: ...II Operation ...
Page 109: ...II 50 blank ...
Page 110: ...III Other ...
Page 123: ...III 14 III 2 5 Dimensions Main Unit ...
Page 128: ...III 19 blank ...
Page 129: ...III 20 blank ...
Page 145: ...III 36 blank ...
Page 165: ...III 56 blank ...