I- 46
If you would like to upload later on, you can
also save all set parameter into your PC.
To upload file saved into your PC to flowmeter,
select “Download/Upload” tab as below.
Select “Upload” tab and open the parameter file.
Then click Upload button as below indicated.
Then please go to (18).
Transducer installation should be completed.
Pipe should be full-filled with fluid.
Flow should be stable enough.
(18) Automatic Gain Adjustment
Open "Basic" - "Gain Adjust".
Click "AGA" button.
Then "AGA window" pops up on the display.
You can adjust the amplifier of the gain in
order to obtain optimum echo reception.
You may select "ALL paths" at once or select
each path individually.
When you can not complete AGA settings in
success, please refer to below and try again.
Otherwise please contact our representatives.
Manual Gain function is used by a person who
can monitor the receiving waveform of the
Amp-out terminal on the main PCB with an
oscilloscope.
Meaning of Error Messages are the follows.