III-24
(4) Data Format
Detail format output from DIGITAL port 1 is as follows,
[Sample Data]
$,F,0.000,0.000,,,,E+3:m3/h,0.000,m/s,0000000,x1m3,,,,,,ROFF,R1,,,,,OVER,,,,,ITG,*06[CR][LF]
Data output from UFL-20A are referred to as a line of data interchange. Data items in each line
are contained in data FIELDs which are numbered, for example "field 0", "field 1" and so on until it
ends at "field 28". Each data FIELD contains a single data VARIABLE. The order of data
FIELDs on each line is defined by a data HEADING "$", with the rest of the data line written in
[CR][LF] code. The data field HEADINGs and data VARIABLEs on each line are separated by
commas.
Empty data FIELDS are enclosed by double quotes, ",,,,".
The applicable FIELDs of data are as follows,
Table 4.1
Field Data
Field No.
Data Description
Sample
0
Header
This character indicates the start of the line.
$
1
Operation mode
F ; FLOWMETER
V ; VELOCITY
F
V
2
Flow volume
Flow velocity (in case of velocity mode)
Result of average flow volume or flow velocity from each path.
Main unit parameters determine numerical digits and decimal
fractions.
Any compensation settings are included in this result.
0.123
-0.123
12.3
123.456
3
Flow volume of path no.1
Flow velocity of path no.1 (in case of velocity mode)
Same as field 2
4
Flow volume of path no.2
Flow velocity of path no.2 (in case of velocity mode)
Same as field 2
5
Flow volume of path no.3
Flow velocity of path no.3 (in case of velocity mode)
Same as field 2
6
Flow volume of path no.4
Flow velocity of path no.4 (in case of velocity mode)
Same as field 2
7
Measuring Unit for flow rate
This unit is set by main unit parameters.
Double quotes ":" will be inserted between exponential
indicators and measurement units.
If the exponential indicators are set as x1, double quotes ":"
are omitted and only units are indicated.
m3/h
m3/min
E+3:m3/h
E-3:L/s
m/s
ft/s
8
Velocity
During flowmeter operation mode, this value is calculated from
flow volume.
During velocity operation mode, this value is calculated from
measured velocity with all compensation parameters such as
"zero shift", "span correction" and "low-cut" functions added.
Decimal fraction is fixed at 3 digits.
This value will be the same as field No.2 in case of velocity
mode.
0.123
1.234
12.345
-0.123
-12.345
Summary of Contents for UFL-30
Page 1: ...Doc No KF08 001J Ultrasonic Flowmeter UFL 30 Installation Operation Manual ...
Page 11: ... 10 blank ...
Page 12: ...I Installation ...
Page 60: ...II Operation ...
Page 109: ...II 50 blank ...
Page 110: ...III Other ...
Page 123: ...III 14 III 2 5 Dimensions Main Unit ...
Page 128: ...III 19 blank ...
Page 129: ...III 20 blank ...
Page 145: ...III 36 blank ...
Page 165: ...III 56 blank ...