background image

 

 

 

 

Certificate of quality and completeness 

 

Type 

: ………………………………………………………… 

Serial number 

: ………………………………………………………… 

Power supply 

: ………………………………………………………… 

Range 

: ………………………………………………………… 

Pressure overload 

: ………………………………………………………… 

Accuracy 

: ………………………………………………………… 

Technical inspection of offset 

: ………………………………………………………… 

Technical inspection of range 

: ………………………………………………………… 

Display data 

: ………………………………………………………… 

Manufacture date 

: ………………………………………………………… 

Warranty period 

: ………………………………………………………… 

Signature: 

: ………………………………………………………… 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

BD SENSORS s.r.o. 

 Hradiš

ť

ská 817 

 687 08 Buchlovice 

Tel. 572 432 111 

572 432 116

 E-mail: [email protected] 

 
PCB2 

Rev. 5/04 

 

Operating instructions for 

Pressure sensor, PCB+ type, two wires, 4 … 20 mA 

Description 
Pressure sensors of the PCB+ type are used to measure very small pressures (relative and differential ones). The 
measured pressure is sensed by a semiconductor strain-gauge sensor or a ceramic capacitive sensor. The sensors are 
designed for gases. In case of a semiconductor sensor, gases have to be non-aggressive and dry. 
The sensors are not manufactured in the EX design. 
The sensors are adjusted at the factory. Further calibration has to be performed according to calibration instructions. 

Selected technical parameters: 

Pressure ranges: 

0.6 kPa to 100 kPa 

Accuracy: 

0.5% (1%) of range according to range and type of used sensor 

Supply voltage range: 

19 to 31 VDC (12 to 31 VDC for sensor without display) 

Influence of supply voltage on accuracy:   max 0.05% of range / 10 V 
Output signal:  

4 to 20 mA, two wires (max. load ((Un (V) - 19) / 0.02) 

Ω

Influence of load resistance: 

max.0.05% of range / 10 V 

Power polarity reversal resistance and short circuit resistance at the output:   permanent. 
  

semiconductor sensor 

capacitive sensor 

Operating range of temperatures : 

-40°C to 80

°

0°C to 60°C 

Compensated range of temperatures : 

0°C to 60°C 

10°C to 40°C 

Influence of temperature in the compensated range of temperatures  

a. zero: 

0.1 … 1.8% of range / 10°C 

depends on the pressure range and the sensor type 

b. range: 

0.1 … 1.8% of range / 10°C 

depends on the pressure range and the sensor type 

Material of the box: ABS 

Fig. 1 Mechanical dimensions: 

Fig. 2: Location of terminal blocks and adjusting elements on the 
printed circuit board 
(view with the removed cover of the sensor in 
a vertical position) 

 

 

Mechanical assembly 
The sensor should be fixed using four clips on the housing. The sensor cannot be placed in an immediate proximity 
of interference sources (transformers, transmitters, motors) and heat sources. Shocks or vibrations at the installation 
site can cause an error. Correctly, the sensor has to be mounted in a vertical position (pressure inlets oriented down). 
In this position, the sensors are adjusted at the factory. This position prevents a condensate from the penetration into 
the sensor. WARNING! Prior to mounting, make sure that there is no liquid in the threaded insert of the closed 
valve. Remaining liquid has to be removed properly. The sensor cannot be mounted if there is liquid in the thread. 

Connection of the measured pressure (using 1/4“ hose) 
The higher pressure is connected to the "+" inlet, the lower pressure to the "-" inlet. In case of a risk of water vapor 
condensation, condensation loops have to be created on the hoses. The version of the sensor for measuring the 
relative pressure includes only a single inlet. Blowing into pressure inlets is not allowed. Sensors to be used up to 
100 mbar can be damaged or destroyed by air pressure from lungs. 

Summary of Contents for PCB+

Page 1: ...0 C 0 C to 60 C Compensated range of temperatures 0 C to 60 C 10 C to 40 C Influence of temperature in the compensated range of temperatures a zero 0 1 1 8 of range 10 C depends on the pressure range and the sensor type b range 0 1 1 8 of range 10 C depends on the pressure range and the sensor type Material of the box ABS Fig 1 Mechanical dimensions Fig 2 Location of terminal blocks and adjusting ...

Page 2: ...adjusted settings Control elements for setting the functions For the control two buttons located under a foil can be used The user moves forward in the menu system or increases the values on the display by the button The button is used to decrease the values and to move backward in the menu system The menu system is closed By scrolling the particular menu settings forward and backward the desired ...

Page 3: ... signal From this moment the adjusted ending of the measuring range end point appears on the display although the sensor signal is shifted in the voltage signal ATTENTION Please note that the output signal remains unaffected by this change Entering the data of the basic adjustment of the mechanism Load Defaults The control system of the display is equipped with the possibility to re create the adj...

Page 4: ...about exceeding the range After pressing both the buttons simultaneously the report about exceeding or failing to meet the display range can be activated Only the ON status or the OFF status can be selected Pressing both the buttons simultaneously the settings are closed High Pressure After pressing both the buttons simultaneously the maximum pressure saved during the measurement is displayed If b...