Installing HP Windows 10 PC 

CCP700-B-EN560 & CCP700-C-EN560 

I323

845 

– 

PC 

C

o

nf

ig

ur

at

io

Ins

tr

uc

ti

o

ns

 

 

Summary of Contents for CCP700-B-EN560

Page 1: ...Installing HP Windows 10 PC CCP700 B EN560 CCP700 C EN560 I323845 PC Configuration Instructions ...

Page 2: ...nalyser Temperature probe and Tacho operating correctly If not contact your service agent before proceeding with the PC change over Record Braketester Version if fitted Remove Existing PC Close down all applications and power off Remove the rear Panel of the Trolley Remove all plugs and lift the PC out through access below keyboard The PC is held in place with Velcro Remove the keyboard and mouse ...

Page 3: ...r keyboard and mouse Plug the Bluetooth dongle into one of the USB ports on the front of the PC The dongle must stay in the first USB port it is plugged in to Note some models of the Laird dongle and certain Belkin devices are not compatible with Win 10 These will require to be replaced Plug in the power cable Turn on your new PC Turn on the Gas analyser and Smokemeter 1 Keyboard 2 Mouse 3 Printer...

Page 4: ...680 Gas Analyser Configuration 1 Open Control Panel 2 Open Hardware and Sound and then Device Manager ...

Page 5: ... analyser USB cable and note which COM port it uses 5 Enter Program Configuration Utility 6 Click the Start button 7 Scroll and click on the Crypton folder 8 Click on the Platform Configuration folder 9 Click on Platform Configuration Utility ...

Page 6: ...10 Click on the Gas analyser tab and set the com port to match that shown on the device manager 1 Enter the COM port identified in device manager Select Gas Analyser Select Wired 2 3 4 Click Save ...

Page 7: ...emperature Probe Tachometer Bluetooth Configure DX260 Smokemeter 1 Select Battery Tach 2 Select Wireless 3 Enter the Bluetooth Address found on the white label under the barcode next to BTID on the CDSS6 Battery Tach casing 4 Click Save ...

Page 8: ...00401 Oil Temp Probe 5 Select Oil Temp 8 Click Save then Exit 6 Select Wireless 7 Enter the Bluetooth Address that is found on the white label under the barcode next to BTID on the DAS00401 Oil Temp Probe ...

Page 9: ...Cabled Connect each device in turn and note in device manager the com port allocated 1 Select Smokemeter 2 Select Wired 3 Enter the COM port identified in device manager 4 Click Save ...

Page 10: ...program and check the equipment is communicating by running a test 5 Select Battery Tach 6 Select Wired 7 Enter the COM port identified in device manager 8 Click Save 9 Select Oil Temp 10 Select Wired 11 Enter the COM port identified in device manager 12 Click Save then Exit ...

Page 11: ...the tools and setup option of the Petrol emissions analyser program Change and save by clicking forward arrow Fig 2 Fig 1 Fig 2 Smoke From the main diesel screen select the additional menu Fig1 Then select VTS entry Fig 2 under the tools and setup option of the diesel smoke meter e program Change and save by clicking forward arrow Fig 3 Fig 1 Fig 2 Fig 3 ...

Page 12: ...Printer Installation Open Control Panel Go to Devices and printers Click Add a device and follow the on screen instructions You may need to download a driver from your printer manufacturer s website ...

Page 13: ...ypton A Brand of the Continental Corporation With all the quality service and backup you would expect from a UK company with a long standing history like Crypton E O E The Company reserves the right to introduce improvements in design or specifications without prior notice The sale of this product is subject to our standard terms conditions and relevant product warranty ...