II-29
f. Dampen Output fluctuation (Change Smoothing parameter)
Display Menu No. : INP-16 : SMOOTHING
Initial value
: “ 015 sec. ”
Range of Input
: 0 to 120 (sec.)
Note :
This value means the time until measuring flow rate reaches 90% by step-up increment.
If the time is extended close to 120 sec., the output will be dampened well against fluctuation.
(The output response against fluctuation will be inertial.)
(3) Analog Output relation (4-20mA Current Output)
a. Change output pattern (4-20mA current output pattern)
Display Menu No. : INP-131 : A-OUT TYPE
Note :
Regarding the details of each pattern, refer to "Chapter III-2-5 Table 1; Analog Output Profile"
.
Summary of Contents for UFL-30
Page 1: ...Doc No KF08 001J Ultrasonic Flowmeter UFL 30 Installation Operation Manual ...
Page 11: ... 10 blank ...
Page 12: ...I Installation ...
Page 60: ...II Operation ...
Page 109: ...II 50 blank ...
Page 110: ...III Other ...
Page 123: ...III 14 III 2 5 Dimensions Main Unit ...
Page 128: ...III 19 blank ...
Page 129: ...III 20 blank ...
Page 145: ...III 36 blank ...
Page 165: ...III 56 blank ...