I- 47
[Error Messages]
aa) “bW” : Bubble Warning
The error will be indicated when pulse height
fluctuates during AGA setting due to fluid
conditions like air bubble contained.
In such case, you might be required flow
condition change or change path method to
shorter path. (ex. V method to Z method.)
Then try again AGA function.
bb) “wW” : Wave distortion Warning
The error will be indicated when required ratio of
pulse height for AGA setting can not be kept due
to pipe conditions like inner corrosion.
In such case, you might be required mounting
position change or change path method to
shorter path. (ex. V method to Z method.)
Then try again AGA function.
cc) “ROFF” : No receiving echo Warning
The error will be indicated when any echo can
not be detected on transducers.
- Mounting distance
- Mounting direction
- Cable connection
- Fluid condition
- Pipe condition
- Parameter settings
…. and so on.
In such case, please check each cause and
improve. Then try again AGA function.
(19) Final check
Open "Monitor-Measurement data".
Commissioning is completed when the
flowmeter starts to show flow rate
measurements without any alarm indication.
Item
Instruction
Communication
Com. status between PC and Main unit
Breakdown
Breakdown alarm
ROFF
No receiving echo warning
Over
Limit alarm
INTEG (Manual)
Totalizing status
(Manual or Timer mode)
INTEG (Timer)
Disturbance
Disturbance detection function status
Low range
Low range detection
Check
Check mode indication
Full scale
Full scale error when PV exceeds
Low Battery
Low battery alarm
AGC
Auto Gain Control function status
Flow rate
Measured flowrate
Path X
Measured flowrate at each path
Velocity
Averaged velocity
Fw Total
Forward totalizing value
Bw Total
Backward totalizing value
ROFF / DIS.
Detection history (Q’ty)
Total Status
Totalizing function mode status
Remaining Time
Time indicates when timer mode
Go to Chapter II "Operation "
for setting output signals.
Summary of Contents for UFL-30
Page 1: ...Doc No KF08 001J Ultrasonic Flowmeter UFL 30 Installation Operation Manual ...
Page 11: ... 10 blank ...
Page 12: ...I Installation ...
Page 60: ...II Operation ...
Page 109: ...II 50 blank ...
Page 110: ...III Other ...
Page 123: ...III 14 III 2 5 Dimensions Main Unit ...
Page 128: ...III 19 blank ...
Page 129: ...III 20 blank ...
Page 145: ...III 36 blank ...
Page 165: ...III 56 blank ...