 Supply voltage

 230V AC +%10 -%20, 50/60Hz or 24V AC ±%10, 50/60Hz or optional 9-30V DC SMPS module. 

 Power consumption 

Max. 2VA
2.5mm² screw terminal connection

   %0,01

 Wiring
 Display
 Accuracy
 EMC
 Safety requirements

 EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.) 
 EN 61010-1: 2001 (pollution degree 2, over voltage category II, measurement category I)

ELECTRICAL CHARACTERISTICS

4 digits, 9.1mm, 7 segment red display LED.

OUTPUT

 Auxiliary supply output

 12V DC, Max. 30mA (unregulated)

ENDA

 

ETS1410 PULSE INPUT TACHOMETER

1/2

SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ.
Yukarý Dudullu 

 34775 - ÜMRANÝYE/ÝSTANBUL/TÜRKÝYE

Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. Kutup Sok. No:20

Panel cut-out

DIMENSIONS

ETS1410-E-02

3

4

m

m

70mm

8mm

85mm

71mm

2

9

m

m

Flush mounting

clamp

Flush mounting

clamp

Depth

Rubber 
packing

Panel

2

1

* 34x77 sized.
* Easy to use.
* Decimal point can be adjusted..
* Process value can be devided by a value 
   between 1 and 999.
* Sampling time is selected automatically 
  according to input frequency. Sampling time is
  between 1 and 16s.
* Having Ce mark according to European Norms.

SET

ENDA

RPM

ETS 1410

TACHOMETER

SIG

SET

ENDA

RPM

ETS 1410

TACHOMETER

SIG

Input 
signal
indicator

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

ETS1410  DIGITAL TACHOMETER

ETS1410-24AC  DIGITAL TACHOMETER

+

  

S

E

N

S

O

R

 I

N

P

U

T

+

  

S

E

N

S

O

R

 I

N

P

U

T

230V AC +10% -20%
50/60Hz  2VA

24V AC ±10% 
50/60Hz  2VA

  

 +

  

1

2

V

 D

C

 3

0

m

A

 O

U

T

  

 +

  

1

2

V

 D

C

 3

0

m

A

 O

U

T

G

N

D

G

N

D

ENDA

 

INDUSTRIAL ELECTRONICS

ENDA

 

INDUSTRIAL ELECTRONICS

SN: XXXXXXXXX

SN: XXXXXXXXX

1

2

3

4

5

6

7

8

9

10

11

12

ET

S1

41

0  

DIG

IT

AL

 T

AC

HO

ME

TE

R

+

  S

E

N

S

O

R

 IN

P

U

T

23

0V

 A

C +

10

% -

20

%

50

/6

0H

z  

2V

A

   

+

  1

2

V

 D

C

 3

0

m

A

 O

U

T

G

N

D

EN

DA

 

IN

DU

ST

RIA

L E

LE

CT

RO

NIC

S

SN

: X

XX

XX

XX

XX

Read this document carefully before using this device. The guarantee will be expired by 
damaging of  the device if you don't attend to the directions in the user manual. Also we don't 
accept any compensations for personal injury, material damage or capital disadvantages.  

Thank you for choosing ENDA ETS1410 TACHOMETER. 

CONNECTION DIAGRAM

ENDA ETS1410 is intended for installation in control panels. Make sure that the device is used
only for intended purpose. 

During an installation, all of 

the cables that are connected to the device must be free of energy. The device must be protected 
against inadmissible humidity, vibrations, severe soiling and make sure that the operation 
temperature is not exceeded. The cables should not be close to the power cables or components. 

The electrical connections must be carried on by a qualified staff

and must be according to the relevant locally applicable regulations. 

 

184-253V AC 
50/60Hz 2VA

Switch

Fuse 

F 100 mA 

250V AC

Neutral

Line

SUPPLY :

NOTE :

Fuse should
be connected.

230V AC Supply

Cable size: 1,5mm²

1) Mains supply cords shall meet the requirements of  IEC 60227or IEC 60245. 
2) In accordance with the safety regulations, the power supply switch shall bring the identification of 

    

the relevant instrument and it should be easily accessible by the operator.

Note :

Holding screw 0.4-0.5Nm 

Equipment is protected throughout
by DOUBLE INSULATION.

HOUSING

 Housing type 
 Dimensions  
 Weight 

 Enclosure material

TECHNICAL SPECIFICATIONS

ENVIRONMENTAL CONDITIONS

 Height

 Maximum 2000m

80%, up to 31

 decreasing linearly 50% at 40

°C

°C

 Ambient/storage temperature
 Max. relative humidity

0 ... +50

/

   

°C -25 ... +70°C (with no icing)

Rated pollution degree

According to EN 60529           Front panel   : IP60

Rear panel    : IP20             

 Do not use the device in locations subject to corrosive and flammable gasses.

ETS1410 

must not be used in location where measurement category is II, III or IV.

INPUTS

 Sensor input

 5 to 30V  pulse
 The device measures frequencies between 0.07 and 3000Hz. 

 Measurement frequency
 Sampling time

 Automatically adjusted according to input frequency. Minimum: 1s,    Maximum: 16s 

 

While cleaning the device, solvents (thinner, benzine, acid etc.) or 

corrosive materials 

must not be used.

 Suitable for flush-panel mounting.
 W34xH77xD70mm 
 ETS1410  : Approx. 200g (after packing the device )
  

 Self extinguishing plastics 

 Note :  1) Panel thickness 

    

should be maximum 

    

7 mm.

2)

 

If there is no 60mm 

    

free space at the back 

    

side of the device, it 

    

would be difficult to 

    

remove it from the 

    p

anel.

For removing mounting clamps: 

Push out the flush-mounting 
clamp in

 

direction 

1

 as

 

shown 

in the figure below. Then, pull 
out the clamp in direction 

2. 

  

1

2

Supply Voltage

Order Code

230V AC  +%10 -%20

ETS1410

24V AC  ±%10

ETS1410-24AC

9-30V DC SMPS module

ETS1410-12AC