background image

 

 

 

NARDA 
Safety 
Test 
Solutions 

S.r.l. Socio Unico

 

Sales & Support: 

Via Rimini, 22 
20142 - Milano (MI)

 

Tel.: +39 02 581881  
Fax: +39 02 58188273 

Manufacturing Plant: 

Via Benessea, 29/B 

17035 - Cisano sul Neva (SV) 

Tel.: +39 0182 58641 
Fax: +39 0182 586400 

  

 

               http://www.narda-sts.it

 

 

 

 

 

SERIAL NUMBER OF THE INSTRUMENT 

You can find the Serial Number in a side of the box. 
Serial Number is in the form : 0000X00000. 
The first four digits and the letter are the Serial Number prefix, the last five digits are 
the Serial Number suffix. The prefix is the same for identical instruments, it changes 
only when a configuration change is made to the instrument. 
The suffix is different for each instrument.

 

 
Document PL01EN-00708 –

 

Copyright

 

© NARDA 2020 

 

 

 

 

 
 
 
 
 
 
 
 
 

User’s Manual 

 

PMM PL-01 

 

PULSE LIMITER 

 

Summary of Contents for PMM PL-01

Page 1: ...THE INSTRUMENT You can find the Serial Number in a side of the box Serial Number is in the form 0000X00000 The first four digits and the letter are the Serial Number prefix the last five digits are the Serial Number suffix The prefix is the same for identical instruments it changes only when a configuration change is made to the instrument The suffix is different for each instrument Document PL01E...

Page 2: ...ment must be disposed of in accordance with local regulations This product conforms to the WEEE Directive of the European Union 2002 96 EC and belongs to Category 9 Monitoring and Control Instruments You can return the instrument to us free of charge for proper environment friendly disposal You can obtain further information from your local NARDA Sales Partner or by visiting our website at www nar...

Page 3: ...ation 1 2 Introduction to PL01 Pulse Limiter 1 3 Insertion loss 1 4 Environment 1 5 Return for service 2 Main Specification Page 1 1 1 1 1 2 1 2 1 2 Page 2 1 Main Specification 2 1 3 Preparation for use Page 3 1 Introduction 3 1 3 2 Packing unpacking 3 1 3 3 Initial inspection 3 1 3 4 Preparation for use 3 2 3 5 Equipment cleaning 3 2 ...

Page 4: ...IV Contents Figures Figure 1 1 PMM PL01 Typical frequency response Page 1 1 Tables Table 2 1 Main Specification Page 2 1 ...

Page 5: ...t In case of connection of the device to the power mains make sure before connection that the voltage selected on the voltage switch and the fuses are adequate for the voltage of the actual mains Devices in Safety Class I equipped with connection to the power mains by means of cord and plug can only be plugged into a socket equipped with a ground wire Any interruption or loosening of the ground wi...

Page 6: ...o sul Neva SV ITALY based on the following harmonized European Standards successfully applied Safety EN 61010 1 undated reference applies to all editions EMC EN 61326 1 undated reference applies to all editions declares under its sole responsibility that the product PMM PL 01 Pulse Limiter conforms with the essential requirements of the Low Voltage Directive 2014 35 EU of the EMC Directive EMC 201...

Page 7: ...rom artificial mains network LISN the Pulse Limiter PL01 must be used particularly when very strong interfering signal is suspected The precision input attenuator and the input mixer of the receiver are therefore protected from being damaged On the other hand if the disturbance signal and spikes do not exceed the maximum input voltage permissible for the receiver the use of the Pulse Limiter can b...

Page 8: ...ed to NARDA for service please complete the service questionnaire enclosed with the Operating Manual and attach it to the instrument To minimize the repair time be as specific as possible when describing the failure If the failure only occurs under certain conditions explain how to duplicate the failure If possible reuse of the original packaging to ship the equipment is preferable In case other p...

Page 9: ...t temperature must be 0 to 45 TABLE 2 1 Main specifications Electrical characteristics Performance Limits Insertion loss max Input impedance VSWR with 50 Ohm termination Frequency response Max permissible input power RF input RF output Rated temperature Storage temperature 0 4 dB 50 Ohm 1 25 9 kHz 30 MHz 0 5 W BNC female connector BNC male connector 0 to 45 C 25 to 70 C Document PL01EN 00708 NARDA...

Page 10: ...2 2 Main specifications This page has been intentionally left blank ...

Page 11: ...d be kept until the contents of the shipment have been checked for completeness and the instrument has been checked mechanically and electrically Verify the accessories availability in the shipping container referring to the accessories check list enclosed with the Operating Manual Notify any damage to the carrier as well as the NARDA Representative 3 3 Initial inspection Inspect the Pulse Limiter...

Page 12: ...miter is reaching saturation affecting therefore measurement accuracy In this case the final measurement must be carried out with attenuator inserted taking into account the attenuator value in the test signal reading Before connecting Pulse Limiter to the associated test instrument ensure that an uninterruptible safety earth ground is provided from the main power source to the EMI test receiver p...

Page 13: ...u would like to submit to the attention of our service organization is kept in great consideration Moreover we are continuously improving our quality but we know this is a never ending process We would be glad if our present efforts are pleasing you Should one of your pieces of NARDA equipment need servicing you can help us serve you more effectively filling out this card and enclosing it with the...

Page 14: ...Suggerimenti Commenti Note Suggestions Comments Note ...