USO
RESTRITO
Menus of Disabled Operations and Settings
411
A
p
p
e
n
d
ix
Menu
Disabled operation/setting
Number
Path
7322.5
Engineering Setup >Panel >Xpt
Assign >Main, V/K Pair Assign
Primary 33 to 48, DME Monitor Video, DME Monitor Key, M/E-2 Out1 to
M/E-2 Out4 selection
7322.6
Engineering Setup >Panel >Xpt
Assign >Src Name/Src Color
Primary 33 to 48, DME Monitor Video, DME Monitor Key, M/E-2 Out1 to
M/E-2 Out4 settings
7324
Engineering Setup >Panel >Prefs/
Utility
Selection of following utility commands:
DME Monitor Video ST, DME Monitor Key ST, DME Override
7324.2
Engineering Setup >Panel >Prefs/
Utility >Xpt Module Src/Reg Btn
Assign
Selection of following utility commands:
DME Monitor Video ST, DME Monitor Key ST, DME Override
7325.1
Engineering Setup >Panel >Device
Interface >GPI Input
• Primary 33 to 48 selection when Action is set to Aux Bus Xpt Override
• [M/E-2] selection
• Selection of the following items when Trigger Type is not set to Level in
[M/E-1] (x=5 to 8): Keyx Cut, Keyx Auto Trans, Keyx SS ? Recall
• Selection of the following items when Trigger Type is not set to Level in
[P/P] (x=5 to 8): DSKx Cut, DSKx Auto Trans, DSKx SS ? Recall
7325.3
Engineering Setup >Panel >Device
Interface >GPI Output
• [M/E-2] selection
• Selection of the following items when Trigger Type is not set to Status
in [M/E-1] (x=5 to 8): Keyx SS ? Recall
• Selection of the following items when Trigger Type is set to Status in
[M/E-1] (x=5 to 8): Keyx SS ? Recall, Keyx On
• Selection of the following items when Trigger Type is not set to Status
in [P/P] (x=5 to 8): DSKx SS ? Recall
• Selection of the following items when Trigger Type is set to Status in
[P/P] (x=5 to 8): DSKx SS ? Recall, DSKx On
7326.11
Engineering Setup >Panel
>Operation >Custom Button >Next
Trans All
Key5 to 8 selection
7326.13
Engineering Setup >Panel
>Operation >Key/AUX/Function
Assign
• M/E-2 settings
• Key5 to 8, EXT DME, DME1 V/K, DME2 V/K selection
7331
Engineering Setup >Switcher >Config M/E-2 settings
7331.1
Engineering Setup >Switcher >Config
>M/E Output Assign
M/E-2 settings
7331.2
Engineering Setup >Switcher >Config
>PGM Config
• M/E-2 settings
• [Key5] to [Key8] selection
7331.3
Engineering Setup >Switcher >Config
>K-PVW Config
• M/E-2 settings
• [Key5] to [Key8] selection
7331.6
Engineering Setup >Switcher >Config
>DME Config
All menu operations
7332
Engineering Setup >Switcher >Input
Primary 33 to 48 settings
7332.1
Engineering Setup >Switcher >Input
>CCR
Primary 33 to 48 settings
7332.3
Engineering Setup >Switcher >Input
>FC Input Select
Primary 33 to 48 selection
7333.1
Engineering Setup >Switcher
>Output >Output Assign
• Output 17 to 32 settings
• M/E-2 Out1 to M/E-2 Out4 selection
• DME Monitor 1, DME Monitor 2 selection
7333.2
Engineering Setup >Switcher
>Output >Video Clip
Output 13 to 32 settings
7333.3
Engineering Setup >Switcher
>Output >V Blank/Through
Output 13 to 32 settings
7333.4
Engineering Setup >Switcher
>Output >Safe Title
Output 13 to 32 settings