When Target is Ch1 or Ch2: Aspect, No Action
When Target is Proc: Format
1)
, Aspect, Level Enable,
No Action
For details about “Level Enable,” see “Notes” in
“Making Control Panel GPI Input Settings”
(
1)
Cannot be selected on DME1.
Carrying out level settings
To set the low level and high level, first set the trigger type
to “Level,” then use the following procedure.
1
In the Engineering Setup >DME >Device Interface
>DME1 GPI Input menu (7344.1), select the action to
be set, and press [H/L Set].
The H/L Set menu (7344.2) appears.
2
Select the setting.
3
To apply the selection made in step
2
when the input
is the GPI high level, press [H Set]. To apply the
selection the input is low, press [L Set].
Making DME GPI Output Settings
This sets the GPI output ports and trigger type, and makes
the action settings.
Notes
There is no GPI output in DME1.
1
Open the Engineering Setup >DME >Device Interface
>DME2 GPI Output menu (7344.6).
The output port selection is fixed at 1.
2
In the <Trigger Type> group, select the trigger type.
Status:
Depending on the status, the relay contacts are
closed or opened, or the output is switched
between high and low.
No Operation:
The trigger has no effect on the relay
state or output level.
3
Select the action to be set.
4
Press [Action Set] to confirm the action selection.