41, 42:
MI, MII Alpha-W pulse with second pulse in the old torque direction.
Cause: additional Alpha-W pulses according to p50179.
51, 52:
MI, MII Alpha-W pulse without second pulse in the old torque direction.
Cause: additional Alpha-W pulses according to p50161.
60, 61, 62:
M0, MI, MII torque direction according to p51840 (simulation operation).
71: MI the command "simultaneously fire all thyristors" (according to p50176) was performed.
81: MI the torque direction specified by the thyristor check was realized.
82: MII the torque direction specified by the thyristor check was realized.
95, 96, 97:
M0, MI, MII the torque direction of the parallel switching master was realized.
Note:
This parameter is only for internal SIEMENS troubleshooting.
Description:
Displays the number of zero current signals of the armature current.
For scan values below the threshold I = 0, the counter is incremented.
The counter is reset in the following cases:
- firing pulse.
- scan value above the threshold for I = 0.
Note:
This parameter is only for internal SIEMENS troubleshooting.
The scan values are every 62.5 µs.
The threshold for I = 0 is 1 % of the rated unit current.
Description:
Displays the thyristor code.
Bit 0 = 1: Thyristor 1 was fired
...
Bit 5 = 1: Thyristor 6 was fired
Bit 6 = 1: thyristors were fired for torque direction 1
Bit 7 = 1: thyristors were fired for torque direction 2
Note:
This parameter is only for internal SIEMENS troubleshooting.
r52982
Armature current zero current signal / Ia I=0 signal
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
8054
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r52983
Thyristor code / Thyr_code
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
8054
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Summary of Contents for SINAMICS DCM
Page 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Page 2: ......
Page 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1203: ......