SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
505
2 Parameters
2.2 List of parameters
Description:
Sets the offset for analog input 2 (X177.29/30) on the CUD.
Description:
Sets the signal processing mode for analog input 2 (X177.29/30) on the CUD.
Value:
0:
Signal not controlled
1:
Signal absolute value generation
2:
Signal inverted
3:
Signal absolute value generation inverted
Description:
Sets the signal source for inverting the signal from analog input 2 (X177.29/30) on the CUD.
1 signal: Inversion
0 signal: No inversion
Description:
Sets the time constant for smoothing the signal from analog input 2 (X177.29/30) on the CUD.
Description:
Sets the signal source for enabling analog input 2 (X177.29/30) on the CUD.
p50722
CUD analog input 2 offset / CUD AI 2 offs
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
2080
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
0.00 [%]
p50723
CUD analog input 2 signal processing / CUD AI 2 sig proc
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Integer16
Dyn. index:
-
Func. diagram:
2080
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 3
0
p50724
BI: CUD analog input 2 inversion / CUD AI 2 inv
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
2080
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p50725
CUD analog input 2 smoothing time constant / CUD AI 2 T
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
2080
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 [ms]
10000 [ms]
0 [ms]
p50726
BI: CUD analog input 2 signal source for enable / CUD AI 2 ena sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
2080
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
1
Summary of Contents for SINAMICS DCM