SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
435
2 Parameters
2.2 List of parameters
Description:
Sets the smoothing time for the line voltage for the EMF setpoint reduction.
Dependency:
Refer to: p50286, p50287, p50288, p50289, r52294
Description:
Sets the upper limit for the line voltage for EMF setpoint reduction.
Dependency:
Refer to: p50287, p50288, p50289, r52294
Description:
Sets the lower limit for the line voltage for the EMF setpoint reduction.
Dependency:
Refer to: p50286, p50288, p50289, r52294
Description:
Sets the evaluation factor for the EMF setpoint reduction.
Dependency:
Refer to: p50286, p50287, p50289, r52294
Description:
Sets the signal source to activate the EMF setpoint reduction.
Dependency:
Refer to: p50285, p50286, p50287, p50288, r52294
p50285[0...n]
EMF setpoint reduction line voltage smoothing time / EMF set line t_sm
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6895
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [s]
10.00 [s]
0.00 [s]
p50286[0...n]
EMF setpoint reduction line voltage upper limit / EMF set line upper
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6895
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
100.0 [%]
150.0 [%]
110.0 [%]
p50287[0...n]
EMF setpoint reduction line voltage lower limit / EMF set line lower
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6895
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
0.0 [%]
100.0 [%]
0.0 [%]
p50288[0...n]
EMF setpoint reduction evaluation factor / EMF set eval_fact
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6895
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
0.0 [%]
200.0 [%]
100.0 [%]
p50289[0...n]
BI: EMF setpoint reduction activation signal source / EMF set act sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dyn. index:
CDS, p0170
Func. diagram:
6895
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0