2 Parameters
2.2 List of parameters
SINAMICS DCM
418
List Manual (LH8), 02/2015, 6RX1800-0ED76
Description:
Sets positive torque limit 1.
Dependency:
Refer to: p50182
Note:
If torque limit changeover is selected (p50694 = 1) and the speed is higher than the set changeover speed (p50184),
then torque limit 2 is activated in place of torque limit 1.
Description:
Sets negative torque limit 1.
Dependency:
Refer to: p50183
Note:
If torque limit changeover is selected (p50694 = 1) and the speed is higher than the set changeover speed (p50184),
then torque limit 2 is activated in place of torque limit 1.
Description:
Sets positive torque limit 2.
Dependency:
Refer to: p50180
Note:
If torque limit changeover is selected (p50694 = 1) and the speed is higher than the set changeover speed (p50184),
then torque limit 2 is activated in place of torque limit 1.
Description:
Sets negative torque limit 2.
Dependency:
Refer to: p50181
Note:
If torque limit changeover is selected (p50694 = 1) and the speed is higher than the set changeover speed (p50184),
then torque limit 2 is activated in place of torque limit 1.
p50180[0...n]
Torque limiting torque limit 1 positive / T lim 1 pos
DC_CTRL
Can be changed:
C2(1), U, T
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6825
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
-300.00 [%]
300.00 [%]
300.00 [%]
p50181[0...n]
Torque limiting torque limit 1 negative / T lim 1 neg
DC_CTRL
Can be changed:
C2(1), U, T
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6825
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
-300.00 [%]
300.00 [%]
-300.00 [%]
p50182[0...n]
Torque limiting torque limit 2 positive / T lim 2 pos
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6825
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
-300.00 [%]
300.00 [%]
300.00 [%]
p50183[0...n]
Torque limiting torque limit 2 negative / T lim 2 neg
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6825
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
-300.00 [%]
300.00 [%]
-300.00 [%]
Summary of Contents for SINAMICS DCM