2 Parameters
2.2 List of parameters
SINAMICS DCM
36
List Manual (LH8), 02/2015, 6RX1800-0ED76
Value:
0:
Ready
29:
Only Siemens int
30:
Parameter reset
Dependency:
Refer to: p0970
Note:
Only the following values are possible: p0010 = 0, 30
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
Description:
Sets the parameter filter for commissioning a Terminal Module 15 (TM15).
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
For the BOP, this setting also causes the read access operations to be filtered.
Value:
0:
Ready
29:
Only Siemens int
30:
Parameter reset
Dependency:
Refer to: p0970
Note:
Only the following values are possible: p0010 = 0, 30
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
Description:
Sets the parameter filter for commissioning a Terminal Module 31 (TM31).
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
For the BOP, this setting also causes the read access operations to be filtered.
Value:
0:
Ready
29:
Only Siemens int
30:
Parameter reset
Dependency:
Refer to: p0970
Note:
Only the following values are possible: p0010 = 0, 30
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
Description:
Sets the password for the Basic Operator Panel (BOP).
Dependency:
Refer to: p0012, p0013
p0010
TM15DI/DO commissioning the parameterizing filter / TM15D com par_filt
TM15DI_DO
Can be changed:
C2(1), T
Calculated:
-
Access level:
1
Data type:
Integer16
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 30
0
p0010
TM31 commissioning parameter filter / TM31 comm par_filt
TM31
Can be changed:
C2(1), T
Calculated:
-
Access level:
1
Data type:
Integer16
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 30
0
p0011
BOP password entry (p0013) / BOP passw ent p13
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
-
P-Group:
Functions
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 65535
0