2 Parameters
2.2 List of parameters
SINAMICS DCM
516
List Manual (LH8), 02/2015, 6RX1800-0ED76
Value:
0:
Not inverted
1:
Inverted
Index:
[0] = DI/DO 4 (X177.15)
[1] = DI/DO 5 (X177.16)
[2] = DI/DO 6 (X177.17)
[3] = DI/DO 7 (X177.18)
Dependency:
The terminal must be set as an output (p50789[0...3]).
Refer to: p50789
Note:
DI/DO: Bidirectional Digital Input/Output
Description:
Sets the signal source for digital input/output 4 (X177.15) on the CUD.
Dependency:
The terminal must be set as an output (p50789[0] = 1).
Refer to: p50789
Description:
Sets the signal source for digital input/output 5 (X177.16) on the CUD.
Dependency:
The terminal must be set as an output (p50789[1] = 1).
Refer to: p50789
Description:
Sets the signal source for digital input/output 6 (X177.17) on the CUD.
Dependency:
The terminal must be set as an output (p50789[2] = 1).
Refer to: p50789
Description:
Sets the signal source for digital input/output 7 (X177.18) on the CUD.
Dependency:
The terminal must be set as an output (p50789[3] = 1).
Refer to: p50789
p50781
BI: CUD digital input/output 4 signal source / CUD DI/DO 4 sig s
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
2060
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p50782
BI: CUD digital input/output 5 signal source / CUD DI/DO 5 sig s
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
2060
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p50783
BI: CUD digital input/output 6 signal source / CUD DI/DO 6 sig s
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
2065
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p50784
BI: CUD digital input/output 7 signal source / CUD DI/DO 7 sig s
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
2065
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0