SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
639
2 Parameters
2.2 List of parameters
Description:
Displays the state of the ramp-function generator.
Description:
Displays the state of the auto-reversing stage.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
04
Direction of rotation enable
No enable
Enable
3135
08
Jog ON command
ON
OFF
3125
09
Creep ON command
ON
OFF
3130
10
Fixed setpoint bypass ramp-function
generator
ON
OFF
3115
11
Jog setpoint bypass ramp-function
generator
ON
OFF
3125
12
Creep setpoint bypass ramp-function
generator
ON
OFF
3130
13
Fixed setpoint input active
Yes
No
3115
14
Setpoint from AOP/PC active
Yes
No
3113
15
Jog setpoint is zero
Yes
No
3125
r53171.0...5
CO/BO: RFG state / RFG state
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
3150, 3151,
3152, 3155
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Limiting active after ramp-function generator Yes
No
3155
01
RFG output equals zero
Yes
No
3152
02
RFG ramping up
Yes
No
3150,
3152
03
RFG ramping down
Yes
No
3150,
3152
04
RFG setpoint enable present
Yes
No
3151
05
RFG active
Yes
No
3150
r53190.0...12
CO/BO: Armature auto-reversing stage state / Arm stage state
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
6815, 6855,
6860, 6862, 8046
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Torque direction enabled
M0 or MI
M0 or MII
-
01
Torque direction I active
Yes
No
-
02
Torque direction II active
Yes
No
-
03
Torque direction 0 requested
Yes
No
-
04
Torque direction I requested
Yes
No
-
05
Torque direction II requested
Yes
No
-
06
Torque direction change in progress
Yes
No
-
07
Alpha G limit reached
Yes
No
-
08
Alpha W limit reached
Yes
No
-
09
Alpha G limit or Alpha W limit reached
Yes
No
-
10
Positive limit of n, M, I, Alpha reached
Yes
No
-
11
Negative limit of n, M, I, Alpha reached
Yes
No
-
12
Alpha W shift active
Yes
No
-