SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
183
2 Parameters
2.2 List of parameters
Description:
Sets the signal source for the setpoint 2 of the technology controller.
Dependency:
Refer to: p2253, p2256
Description:
Sets the scaling for the setpoint 1 of the technology controller.
Dependency:
Refer to: p2253
Description:
Sets the scaling for the setpoint 2 of the technology controller.
Dependency:
Refer to: p2254
Description:
Sets the ramp-up time of the technology controller.
Dependency:
Refer to: p2252, p2258
Note:
The ramp-up time is referred to 100 %.
Description:
Sets the ramp-down time of the technology controller.
Dependency:
Refer to: p2252, p2257
Note:
The ramp-down time is referred to 100 %.
p2254[0...n]
CI: Technology controller setpoint 2 / Tec_ctrl setp 2
DC_CTRL (Tech_ctrl),
DC_CTRL_R
(Tech_ctrl),
DC_CTRL_R_S
(Tech_ctrl),
DC_CTRL_S
(Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dyn. index:
CDS, p0170
Func. diagram:
7958
P-Group:
Technology
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
0
p2255
Technology controller setpoint 1 scaling / Tec_ctrl set1 scal
DC_CTRL (Tech_ctrl),
DC_CTRL_R
(Tech_ctrl),
DC_CTRL_R_S
(Tech_ctrl),
DC_CTRL_S
(Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
7958
P-Group:
Technology
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [%]
100.00 [%]
100.00 [%]
p2256
Technology controller setpoint 2 scaling / Tec_ctrl set2 scal
DC_CTRL (Tech_ctrl),
DC_CTRL_R
(Tech_ctrl),
DC_CTRL_R_S
(Tech_ctrl),
DC_CTRL_S
(Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
7958
P-Group:
Technology
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [%]
100.00 [%]
100.00 [%]
p2257
Technology controller ramp-up time / Tec_ctrl t_ramp-up
DC_CTRL (Tech_ctrl),
DC_CTRL_R
(Tech_ctrl),
DC_CTRL_R_S
(Tech_ctrl),
DC_CTRL_S
(Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
7958
P-Group:
Technology
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [s]
650.00 [s]
1.00 [s]
p2258
Technology controller ramp-down time / Tec_ctrl t_ramp-dn
DC_CTRL (Tech_ctrl),
DC_CTRL_R
(Tech_ctrl),
DC_CTRL_R_S
(Tech_ctrl),
DC_CTRL_S
(Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
7958
P-Group:
Technology
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [s]
650.00 [s]
1.00 [s]