2 Parameters
2.2 List of parameters
SINAMICS DCM
494
List Manual (LH8), 02/2015, 6RX1800-0ED76
Description:
Sets the signal source for the main setpoint in the context of setpoint processing.
Dependency:
Refer to: p50320, p50322
Description:
Sets the signal source for the additional setpoint in the context of setpoint processing.
Dependency:
Refer to: p50321, p50323
Description:
Sets the signal source for enabling the ramp-up integrator on the ramp-function generator.
Description:
Sets the signal source for activating/de-activating ramp-function generator tracking.
Dependency:
The enable for ramp-function generator tracking must be available (p50317 = 1).
Refer to: p50317
Description:
Sets the signal source for the ramp-function generator's input signal.
p50644[0...n]
CI: Setpoint processing signal source for main setpoint / M set sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dyn. index:
CDS, p0170
Func. diagram:
3135
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
52206[0]
p50645[0...n]
CI: Setpoint processing signal source for additional setpoint / A set sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dyn. index:
CDS, p0170
Func. diagram:
3135
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
0
p50646[0...n]
BI: RFG signal source for ramp-up integrator enable / R-up int ena sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dyn. index:
CDS, p0170
Func. diagram:
3150
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
1
p50647[0...n]
BI: RFG tracking activation signal source / RFG trck act sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dyn. index:
CDS, p0170
Func. diagram:
3152
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p50648
CI: RFG signal source for input signal / RFG inp sig sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dyn. index:
-
Func. diagram:
3151
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
52193[0]
Summary of Contents for SINAMICS DCM
Page 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Page 2: ......
Page 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1203: ......