SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
459
2 Parameters
2.2 List of parameters
Description:
Sets the signal source for the selection of the connectors (p50436[0 to 7]).
Description:
Sets the signal sources for generating the jog setpoint (CO: r52202).
Description:
Setting to enable or disable the impact of the individual jog setpoints when generating signal r53170.11, "Bypass
ramp-function generator".
Value:
0:
Do not bypass
1:
Bypass
Note:
[0] = Enable bypassing of ramp-function generator at jog setpoint 0
...
[7] = Enable bypassing of ramp-function generator at jog setpoint 7
Description:
Sets the signal source for the default setpoint when jog is not selected.
Description:
Sets the signal source for the selection of the connectors (p50441[0 to 7]) for the creep setpoint.
Dependency:
Refer to: p50441
p50435[0...7]
BI: Jog setpoint signal source for connector selection / Jog set conn sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
3125
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p50436[0...7]
CI: Signal source for jog setpoint / Jog set sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / FloatingPoint32
Dyn. index:
-
Func. diagram:
3125
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
0
p50437[0...7]
Jog setpoint bypass ramp-function generator / Jog set bypass RFG
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Integer16
Dyn. index:
-
Func. diagram:
3125
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
p50438[0...n]
CI: Jog signal source for default setpoint / Jog def set sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / FloatingPoint32
Dyn. index:
CDS, p0170
Func. diagram:
3125
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
52208[0]
p50440[0...7]
BI: Creep setpoint signal source for connector selection / Cr set sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
3130
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0