SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
525
2 Parameters
2.2 List of parameters
Value:
0:
Switched off
1:
After the first ON command
2:
After each ON command
3:
After next ON command
Dependency:
Refer to: F60061
Note:
The thyristor test function cannot be used when supplying extremely high inductances (e.g. when supplying a field
from armature terminals, supplying solenoids, etc.) and must be de-activated (p50830 = 0).
When SINAMICS DCM are connected in parallel (6 pulse or 12 pulse), thyristor diagnostics
may only be selected at the master. The thyristor diagnostics is then
first carried out at the master, and then automatically at all of the slaves one after the other. If
a defective thyristor is detected at a SINAMICS DCM, then the corresponding
fault message is initiated at this SINAMICS DCM and not at the master where
thyristor diagnostics was started.
Description:
Sets the trigger resolution for the trace.
Value:
0:
No trigger for start
1:
Start immediately
2:
Start together with STARTER trace
Description:
Setting for starting the procedure to copy the diagnostics file to the memory card.
Value:
0:
Inactive
1:
Start copying procedure
2:
Copy file into User\Data folder
Note:
The value is reset automatically at the end of the copying procedure.
If a diagnostics file is empty, the file written to the memory card will also be empty.
This file will overwrite any existing file on the memory card.
Description:
Setting to test the device fans.
Value:
0:
Stop fan
1:
Start fan
Dependency:
Refer to: r53135
Refer to: F60167
Note:
The status of the fans is displayed in binector outputs r53135.8 to 11.
p50831
Diagnostics memory trace control word / Trace STW
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dyn. index:
-
Func. diagram:
8052
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 2
0
p50832
Diagnostics memory copy recording file to memory card / Copy diag file
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Integer16
Dyn. index:
-
Func. diagram:
8052
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 2
0
p50833
Device fan test / Dev fan test
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Integer16
Dyn. index:
-
Func. diagram:
8047
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0