2 Parameters
2.2 List of parameters
SINAMICS DCM
514
List Manual (LH8), 02/2015, 6RX1800-0ED76
Description:
Setting to invert the signals at the CUD's digital outputs.
Value:
0:
Not inverted
1:
Inverted
Index:
[0] = DO 0 (X177.19)
[1] = DO 1 (X177.20)
[2] = DO 2 (X177.21)
[3] = DO 3 (X177.22)
Note:
DO: Digital Output
Description:
Sets the signal source for digital output 0 (X177.19) on the CUD.
Description:
Sets the signal source for digital output 1 (X177.20) on the CUD.
Description:
Sets the signal source for digital output 2 (X177.21) on the CUD.
Description:
Sets the signal source for digital output 3 (X177.22) on the CUD.
Note:
A restart is required if p50774 is logically combined with (2)r51579.0!
p50770[0...3]
CUD digital outputs inversion / CUD DO inv
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Integer16
Dyn. index:
-
Func. diagram:
2055
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
p50771
BI: CUD digital output 0 signal source / CUD DO 0 sig s
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
2055
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p50772
BI: CUD digital output 1 signal source / CUD DO 1 sig s
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
2055
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p50773
BI: CUD digital output 2 signal source / CUD DO 2 sig s
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
2055
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p50774
BI: CUD digital output 3 signal source / CUD DO 3 sig s
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
2055
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0