SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
469
2 Parameters
2.2 List of parameters
Description:
Sets the signal source for the positive torque limit on the speed limiting controller.
Dependency:
Refer to: r52136
Note:
This parameter specifies which parameter is to be injected as the limit value for torque limiting 1 (r52136).
Description:
Sets the signal source for the negative torque limit on the speed limiting controller.
Dependency:
Refer to: r52137
Note:
This parameter specifies which parameter is to be injected as the limit value for torque limiting 2 (r52137).
Description:
Sets the maximum speed for the positive direction of rotation on the speed limiting controller.
Description:
Sets the maximum speed for the negative direction of rotation on the speed limiting controller.
Description:
Sets the P gain on the speed limiting controller.
p50510
CI: Speed limiting controller signal source for pos torque limit / T lim pos sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / FloatingPoint32
Dyn. index:
-
Func. diagram:
6835
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
52002[0]
p50511
CI: Speed limiting controller signal source for neg torque limit / T lim neg sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / FloatingPoint32
Dyn. index:
-
Func. diagram:
6835
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
52004[0]
p50512[0...n]
Speed limiting controller max speed pos direction of rotation / n_max pos dir rot
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6835
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
0.0 [%]
200.0 [%]
105.0 [%]
p50513[0...n]
Speed limiting controller max speed neg direction of rotation / n_max neg dir
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6835
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
-200.0 [%]
0.0 [%]
-105.0 [%]
p50515[0...n]
Speed limiting controller P gain / n_lim Kp
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6835
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.10 200.00
3.00
Summary of Contents for SINAMICS DCM